Verify that the DIP switches of SW100 un-
der the controller terminal box cover are
in the correct position. Refer to section 10.
Check that back of V-Green 165 is free
from dirt and debris. Use compressed air
to clean.
Check that V-Green 165 is spinning by
looking at fan on back of V-Green165. If
so, check that pump impeller is correctly
installed.
Replace fuse, reset breaker/GFI.
Check connections at J201 connector.
Check that back of V-Green 165 is free
from dirt and debris. Use compressed air
to clean.
Clean strainer basket.
Check plumbing connections and verify
they are tight.
Check if the V-Green 165 can be rotated
by hand and remove any blockage.
Tighten mains wire connections.
Controller DIP switches not
configured properly
Debris in contact with fan
Impeller is loose
Mains Voltage is not present
Over temperature FAULT
Debris in strainer basket
Air leak
User Interface is not connected
Over current FAULT
Loose mounting
Clogged or restricted plumbing
V-Green 165 shaft is locked
V-Green 165 shaft is damaged
V-Green 165 will automatically restart
after one (1) minute.
Check that mounting bolts of V-Green 165
and pump are tight.
Check for blockage in strainer or suction
side piping.
Checked for blockage in discharge piping
including partially closed valve or dirty
pool filter.
Replace V-Green 165.
V-GREEN 165
FAILS
TO START
V-GREEN 165
RUNS
THEN
STOPS
V-GREEN 165
IS
NOISY
V-GREEN 165
RUNS,
BUT NO
FLOW
14 Troubleshooting Guide
Symptom
Possible Causes
Potential Solutions
Diagnosing certain symptoms may require close interaction with, or in close proximity to,
components that are energized with electricity. Contact with electricity can cause death,
personal injury, or property damage. When trouble shooting the V-Green 165, diagnostics
involving electricity should be cared for by a licensed professional.