20
Electrical Installation - continued
T0RQUE DATA
Wire Range
Torque in.-lbs.
14-10 CU
7
8 CU
10
CONTACTOR
RELAY
120V
GROUND
TERMINAL
WHT-2
WHT-2
YEL-2
YEL-1
YEL-2
Coil
120V
GROUND
LOAD 2
LOAD 1
LINE 2
LINE 1
NEUTRAL
BLK-1
WHT-1
STRIP
TERMINAL
2
1
BLK-3
RED-3
RED-1
6
5
4
3
1 PHASE 4-WIRE
Speed
SERVICE
BLK-5
WHT-0
RED-3
RED-2
BLK-2
BLK-5
BLK-3
BJC RATING
1-Circuit 28 Amps
208-240 Volts
60 Hz, 1 Phase
4-Wire Service
GFCI Protected
ON/OFF Controls
C
N/O
N/C
BLK-6
YEL-1
GROUND
SERVICE
Single
Motor
7
YEL-3
BLU-1
YEL-3
BLU-1
To Control
From Control
N/C
N/O
C
Remote Relay
07/03/2014
GFCI
Module
WHT-1
BLK-2
RED-2
ORG-0
YEL-0
ORG-0
BLK-6
Transformer
BLK-4
BLK-4
RED-4
RED-4
C
N/O
N/C
3.5A Fuse
BLU-3
BLU-2
2
1
WHT-4
WHT-4
BLU-4
12 VAC
To L.E.D. RED
To L.E.D. BLK
AIR
SWITCH
(PUMP)
LATCHING AIR
SWITCH (LIGHT)
RED-1
BLK-1
WHT-1
YEL-0
BLK-0
WHT-0
BLK-0
RED-1
BLK-1
BLU-4
BLU-3
NOTE: Use
ONLY
copper
conductors with minimum
75
o
C wire insulation.
NOTE: Use
TO
&
FROM
Control for remote
operation of equipment.
40A Shun
t T
rip
w/ A
ux. Swit
ch
Cir
cuit Br
eak
er
Figure 24A
Control Box Wiring Connections