background image

18

Final Assembly - continued

11. Mount the volume control knob (part #21.1) and air regulator knob (part #111) by means of a rubber mallet and a 
protective cloth. 

(See Figure 23)

21/1

111

46

38/2 38/1

37

37

110

112

Figure 22

Installation of Light Cover 

Figure 23

Installation of Knobs

Electrical Installation

WARNING:

 

The wiring of the pool motor and control box should be done by a licensed electrician in accordance with all local, 

state, and federal codes. Be certain that the motor frame and control box are grounded. Motor name plate has voltage, phase, 
amp draw, and other motor information as well as wiring connection instructions.

This section concerns the electric motor, control box, and metal parts of the BaduJet Imperial. 

CAUTION: Before installing the Speck Pump, read the entire pump owner’s manual found in the pump box.

Consult local codes for minimum distance between pump and pool. Locate pump as close to the pool as practical.

CAUTION: There is 30 ft. of air tubing for the air buttons as well as 30 ft. of cable for the LED light included with the BaduJet 
Imperial. The control box should be installed within this distance of the jet housing. If a longer distance is required, please 
contact the factory regarding the use of smaller diameter air tubing.
 

BONDING: As required by the National Electrical Code, the electric pump motor, stainless steel handles, and stainless steel 
cover must be electrically bonded to the pool structure (reinforced bars, etc.) by a solid copper conductor not smaller than No. 
8 AWG. Bonding lugs are provided on the electric pump motor, stainless steel handles, and stainless steel cover. A 3ft length 
of 8 AWG insulated solid wire (10” of insulation stripped back) is provided with the swim jet. Refer to the 

Bonding Instructions

 

section on pages 16 for installation.

CAUTION:

 

The strain relief MUST be completely tight around the bonding wire. The BaduJet Imperial WILL LEAK if this 

strain relief is left loose!

Summary of Contents for badu jet imperial

Page 1: ...Installation Manual BADU JET IMPERIAL Counter Swimming Unit Rev 03 16...

Page 2: ...pment 2999999303 Rev 0416 SW OO 0 OO Technical Support Address Speck Pumps 8125 Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739...

Page 3: ...Plumbing Installation 7 New Concrete or Gunite Installation 9 Existing Concrete or Gunite Installation 13 Liner and or Fiberglass Pool Installation 14 Bonding Instructions 16 Final Assembly 17 Electr...

Page 4: ...nt parts may be used 5 Acceptable fittings pipe sizes are listed on page 7 of this manual No other sizes are permitted 6 Never exceed the maximum flow rate stated on this product 7 The anti entrapment...

Page 5: ...l or one each on two separate vertical walls WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increased potential fo...

Page 6: ...6 2011 Suction Fittings for Use in Swimming Pools Wading Pools Spas and Hot Tubs and either A B A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release Syst...

Page 7: ...N The discharge connection on the back of the jet housing must be located directly ABOVE the suction connection CAUTION The suction line should remain below water level from the suction connection at...

Page 8: ...reduce the performance of the system The shortest length of pipe with the minimum number of fittings possible should be used to avoid any significant friction loss due to the pipe and fittings NOTE Re...

Page 9: ...NOTE To avoid stress on the housing the jet housing and 2 to 3 inches of plumbing conduit stub out should be encased in gunite or concrete Figure 3 Sample BaduJet Imperial Installation Self Priming 1...

Page 10: ...it to a point above the water line for example at the equipment pad Install the 1 2 check valve part 101 O ring part 113 and 1 2 conduit adapter part 116 at the end of the 1 2 conduit n n Glue the met...

Page 11: ...steel handles part 70 based on your pool construction Mount the gunite cover to the front of the jet housing using the four 4 M8 x 80mm studs part 31 four 4 M8 washers part 32 and four 4 M8 nuts part...

Page 12: ...re 5 to mark and drill the holes through the liner twelve 12 M8 clamping ring screw holes and 13 3 center hole Insert the gasket with knobs in the front of the jet housing part 26 Install the liner wi...

Page 13: ...ide of pool wall 7 Mix compound that is compatible and has a good bonding characteristics to the pool wall compound Pour mixture into form Use a mallet and lightly tap the front of formed assembly to...

Page 14: ...r not silicone is necessary Discharge connection Air Regulator Hose Connection Suction connection Protective Conduit Connection L E D Light Cable Air Hose Bonding Adaptor Figure 11 Jet Housing Rear Vi...

Page 15: ...ng ring screws part 52 9 Follow steps 1 4 under Jet Housing Installation New Gunite or Concrete Construction on page 9 10 10 Continue to Final Assembly Section on page 17 NOTE The gunite cover part 30...

Page 16: ...front of the jet housing See Figure 16 3 After installing the nozzle housing part 102 1 in Final Assembly Section on page 17 pull the bare end of the wire through the bonding lug on the stainless stee...

Page 17: ...94 and four 4 M8 x 20 suction cover screws part 95 All screws should be HAND TIGHT DO NOT use drills or pneumatic tools DO NOT over tighten Make sure the UP label is in the correct position See Figur...

Page 18: ...ween pump and pool Locate pump as close to the pool as practical CAUTION There is 30 ft of air tubing for the air buttons as well as 30 ft of cable for the LED light included with the BaduJet Imperial...

Page 19: ...n GROUNDING Permanently ground the pump motor and control box using a conductor of appropriate size CAUTION DO NOT connect to electric power supply until the unit is permanently grounded Power from m...

Page 20: ...ntrols C N O N C BLK 6 YEL 1 GROUND SERVICE Single Motor 7 YEL 3 BLU 1 YEL 3 BLU 1 To Control From Control N C N O C Remote Relay 07 03 2014 GFCI Module WHT 1 BLK 2 RED 2 ORG 0 YEL 0 ORG 0 BLK 6 Trans...

Page 21: ...ssary High levels of chlorination can be minimized or eliminated through careful water management 6 When shocking the pool the pump should be maintained on its highest speed until chlorine levels retu...

Page 22: ...one 1 winter plate one 1 gasket four 4 M8 washers and four 4 M8 x 30mm screws See Figure 27 Also you can protect your swimjet system as follows Drain pool until water level has dropped below the anti...

Page 23: ...air from the top of the water level If installed too low a good swim lane cannot be developed Can the pump be placed below water level Yes However for best performance we recommend ordering a pump fo...

Page 24: ...Bad bearings Check for noise when shaft is turned by hand Motor will be very hot in bearing area when running Replace bearing 5 Motor runs hot These motors will run hot to the touch however this is n...

Page 25: ...a short piece of air tubing to the L E D air switch Blow into tube and check if L E D turns on off Contact certified electrician to diagnose control box components 9 The volume control knob keeps spin...

Page 26: ...28 102 1 61 70 95 93 1 94 93 110 112 37 38 1 38 2 111 21 1 47 62 9 4 48 23 102 64 65 66 67 63 109 108 58 56 54 59 60 102 1 22 21 107 6 4 101 25 20 113 114 115 116 117 118 31 32 33 98 119 26 6 Product...

Page 27: ...EALING CORD GASKET WITH KNOBS JET HOUSING GASKET CLAMPING RING RING CLAMPING GUNITE COVER STUD GUNITE COVER M8 x 80mm WASHER GUNITE COVER M8 NUT STUD GUNITE COVER M8 A2 O RING PNEUMATIC BUTTONS 24 x 3...

Page 28: ...be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations to Buyer or with respect to the Badu SwimJet System s in the event of the occ...