10
SYSTEM ERROR SCREEN
This is the “System Errors Screen” (See Figure 7).
• Press MODE to continue on to the “Home Screen”
or
• Press the UP (arrow key) or DOWN (arrow Key)
to view the system errors. (See Table 2.0 for
description)
North American Version Only.
System Error Screens
“Error” Code
Error Description
Cause
Microprocessor
Microprocessor fault
Microprocessor Start-Up
Under Voltage
Low voltage
Voltage must exceed < 208V AC control
activates itself independently when voltage
exceeds 208V for more than six (6) seconds
(Motor Activates)
Temperature
Temperature too high
Temperature too low
Temperature Too High > 100
o
C (212
o
F)
Temperature Too Low < -20
o
C (4
o
F)
Overload
Thermal overload tripped
Motor is drawing to many amps. Over current
protection has tripped.
Over Voltage
High voltage
Voltage has exceeded 269V AC (Surge)
Shaft Locked
Shaft locked
Impeller or pump locked/motor shaft stopped
turning.
Self test
Self-test
One or more self-test were not completed or
failed.
Phase
Motor Fault
Phase loss. A wire on the motor has become
disconnected.
Other
Other Fault
Any fault not covered by other codes.
Table 2.0
CHANGING THE LANGUAGE
The controller comes with English as the default
language and will have one of three (3) additional
languages available.
• Unplug the wall transformer.
• Hold down two buttons as indicated in Table 3.0
and insert the wall transformer.
• The new language will appear in the bottom right
hand corner of the screen (See Figure 8). The
buttons can be released and the new language
will now become the default language.
Languages
Figure 8
System errors
Touch II
v1.05
ENG
28-OCT-11
Figure 7