background image

INSTRUCTIONS FOR MODELS

92-SE-4930-01

For additional assistance or service please contact:

SPEAKMAN

®

 Company

400 Anchor Mill Road
New Castle, DE 19720

800-537-2107

[email protected]

www.speakman.com

SE-4930

SE-4930

GRAVITYFLO

Freeze Protected Jacket

3 Year Limited Warranty

Additional warranty information can be found at: 
www.speakman.com

WARRANTY

MAINTENANCE

Be sure to wear eye protection during assembly and 

mounting.

SAFETY TIPS

Always disconnect power while servicing the unit and 

Always disconnect power while servicing the unit and 
allow the unit to cool down before filling with water.

allow the unit to cool down before filling with water.

Occasional cleaning and disinfection is recommended. 
To clean the inside of the unit, add 1/2 cup (4 fluid 
oz.) of Clorox (liquid bleach) to a full tank of potable 
water. Allow the mixture to penetrate for 15 minutes. 
Drain tank, and rinse thoroughly several times with 
potable water. Take care to not overtighten drain cap 
as damage may occur. For further information about 
Clorox, call toll-free at 1-800-292-2200. Follow 
refilling instructions in this manual and place the tank 
back in service. Should any repair part be required, 
use only genuine SPEAKMAN parts for repair or 
replacement. See available replacement parts in this 
document, to order parts call 1-800-537-2107.

As part routine inspection, the unit shall be checked for 
adequate water level. (Within 5" of the top cap)

TOOLS AND SUPPLIES

Flat Tip

Screwdriver

Adjustable

Wrench

Measuring

Tape

Safety

Glasses

Slip Joint

Wrench

Phillips

Screwdriver

1

Remove the Drain Plug or Drench Hose (if 
equipped) and drain the unit completely.

2

If your unit has as Hose Clip installed, 
remove it at this time. Reinstall the self 
tapping screw to seal hole.

3

Disassemble drain parts from unit. Remove 
Drain Nut (3) with wrench. Remove Drain 
Washer (2) from threading of the Drain 
Fitting. Remove Drain Fitting (1) through 
openings in the Tank and Wall Bracket. 

4

Using a screwdriver, pry the lower 
portion of the Wall Bracket away from 
the recess on the Tank.

5

Remove the empty Tank from the Wall 
Bracket completely. 

Unsnap the Wall 

Bracket from the recess of the bottom of 
the Tank (1). “Unhook” the top of the 
handle of the Tank from 

the Wall Bracket

 

(2). 

6

Thoroughly clean and ensure the top area 
of the tank is free of dirt and debris before 
adhering Electronic Controller Box to 
handle area.

7

Remove Tape Release Liner (x4) on bottom 
of Controller Box to expose tape.

8

Ensure Digital Read Out Interface is facing 
forward. 

The control box should be placed 

1 - 1

1

/

2

” from the handle to allow for 

clearance of the mounting bracket.

1-1½”

9

Slide Tank Assembly (1) into Heated 
Jacket (2) 

and assure the heating pad is 

not folded and lying against the tank

.

10

Place Power Supply Cable (1) inside of 
Tank Jacket. Pass the AC cord through 
the Jacket Access Panel (2) located on 
the upper left side panel.

 

Verify AC plug 

adapter is fully extended through the 
Jacket (2). Velcro Jacket Access Panel 
closed.

11

Connect 3 Pin Wiring Harness from Jacket 
to Controller.

IMPORTANT

Product is designed to be used indoors

Product is designed to be used indoors
and outdoors.

and outdoors.

When mounted in outdoor conditions, product must be 

When mounted in outdoor conditions, product must be 
in a covered area and not directly exposed to outdoor 

in a covered area and not directly exposed to outdoor 
elements such as rain and snow.

elements such as rain and snow.

ANSI Z358.1 requires that all self-contained eyewash 
shall be visually inspected weekly, unless the product 
is placed in environments with extreme conditions that 
may affect the form, fit, or function of the unit 
(temperature, dirt, etc.). If this is the case, then the 
inspection should be conducted more often as the end 
user deems necessary. Speakman Company furnishes 
a testing record tag (91-0635) with each unit. On this 
tag, the date of inspection and the inspectors’ initials 
should be noted. ANSI Z358.1 specifies that the 
height of the spray heads is to be between 33” - 45” 
from the floor. The SE-4330 unit weighs approximately 
185 lbs filled. Ensure the mounting surface (wall, etc.) 
and mounting hardware can safely hold a minimum 
vertical load of 300 lbs. Be sure to read instructions 
thoroughly before beginning installation. Do not 
overtighten any connections or damage may occur. 
The unit should be full at all times, to achieve the 
minimum 15 minute run time as stated by ANSI, in 
case of an emergency. Refill the tank to a full level 
after each activation. Before refilling tank dry and 
clean outside of spray heads, and inside of pull strap 
to remove debris, and to assure proper sealing.

WARNING: This units maintains the water
temperature within the tepid range of 60-90 F. 
Depending on the water temperature within the tank 
and the ambient conditions, it may take up to
24 hours for the water temperature to reach the
tepid range during initial start-up. If noted during 
inspection the water temperature is outside that
range, the product should be taken out of service
and the condition troubleshooted.

Reviews: