User’s manual
EXPERT 1K-FA
Pag. 19 of 76
After checking your wiring, re-install the plastic protection, the bottom cover and make
sure that, when using 115 and 100 Vac, in “Fuse 1” there is a 1A fuse and in “Fuse 2”
there is a 20A fuse (included in the packaging).
Mark the voltage change on the back panel.