Instruction Manual of PR968X Model Controller
-
3
-
I
、
Brief Introduction
1.
General Description of Functions
Model
Functions
PR9681
PR9681M
PR9683
PR9683M
1.
LOCK
√
√
√
√
2.
PUMP
√
√
√
√
3.
BLOWER
√
√
√
√
4.
Thermostatic Heating
√
√
5.
TEMPRETURE SENSOR
√
√
6.
LAMP
√
√
√
√
7.
FM DIGITAL TURNNING RADIO
√
√
√
√
8.
PLAY CD PROGRAM
√
√
9.
MP3
√
*
√
10. WATER LEVEL DETECTION
√
√
√
√
11. OZONE
*
*
*
*
12. CLEANNING
*
*
*
*
13. REMOTE CONTROL
√
√
√
√
√:with this function; X: without this function;
*:optional function
2. Controller System Including
:
1)
Control panel(1)
;
2)
Control electric box(1).
3)
Remote (1).
3. Characteristics of the Controller
1)
Rated voltage :AC220V-240V
2)
Working voltage range:AC200V-248V
3)
Rated power :50HZ/60HZ
4)
Controllable current: <25A
5)
Power consumption:<10W (all loads OFF)
6)
Applied ambient temperature :+5℃ ~ +40℃
4.
Devices controlled by the controlling system
1)
Pump :AC220V/2HP
2)
Themostatic heating : AC220V/2000W
3)
Blower : AC220V/1HP
4)
Lamp : AC12V/20W
5)
Ozone generator : AC12V/6W
6)
Solenoid : DC12V/5W
7)
Loudspeaker : 8Ω/10W
5.
The LCD shows the following information