Operation instruction manual of model:PR968x
-
8
-
on.
8.2 When the system is on
,
press “
、
” to choose the HEAT
function
,
when cursor select “Heat”
,
press“
” to turn on the
heater
:
8.2.1 2 Thermostatic heating function starts or stops according to
the temperature
(
the temperature that the system defaults is
37
o
C
)
:
Controlling rule is as follows:
If the temperature≥setting temp1
℃,
stop heating
;
If the temperature≤setting temperature -1
℃,
start heating.
8.3 Press “
” again to turn off the heater.
8.4 Temperature adjustment
8.4.1 When the thermostatic heating function is on, press
till
temperature valueblinks,then press “
” or“
” once
,
temperature shall be increased or decreased 1
℃ ;
if
press“
”or“
”over 2 seconds
,
temperature will increased
or decreased at the speed“1
℃
/0.5 s”
;
without any operation
for 5 seconds, LCD will display the water temperature.
8.5 Temperature setting range
:
30
℃
--45
℃
.
8.6 When the temperature sensor error, LCD shows “E1” and the
buzzer sounds : di…di…
,
thermostatic heating function will not
work.