SR85 REMOTE CONTROL CAR ALARM SYSTEM
9
YELLOW WIRE-ELECTRIC FAN INHIBIT
IMPORTANT:
If you have a mechanical cooling fan or the electric
fan does not operate with the ignition turned off,
then the yellow wire MUST be connected to a
good earthing point BEFORE connecting the RED
wire of the alarm.
If the electric cooling fan still operates when the ignition is turned
OFF then a connection from the SR85 must be made to prevent the
current sensing function from false triggering the alarm. The cooling
fan wiring will be configured as shown in Fig. 4 or 5.
NOTE: The engine must be cold before proceeding.
Locate the fan thermal switch by tracing the wiring from the fan
motor. Connect the YELLOW wire as shown in Fig. 4 or Fig. 5 using
a solder joint or a crimp termination to the wire which runs between
the fan motor and thermal switch.
Fig 4
Fig 5