TECHNICAL SUPPORT - tel. +48 71 31 59 068
USE
1.
At least once per month run the device test using "Test / Hush"
button.
2.
Remove the dust from the device cover.
3.
When the battery is almost empty it will be indicated with a single
audible sound and the red "Alarm" LED which will blink at approx. 40
sec. interval. The battery should be immediately replaced.
4.
The self-diagnostic system allows to check for a potential malfunc-
tioning of the device. In that case the device will trigger an audible
alarm (one signal every 30 sec.) and an optical alarm - indicated by a
flashing "Fault" LED.
PRECAUTIONS AND MAINTENANCE
Remember that because of technical restrictions (e.g. device malfunc-
tion, low battery) and the installation location, carbon monoxide sen-
sors do not guarantee in 100% the detection of carbon monoxide but
increase the probability of early detection of the dangerous concentra-
tion. It is important to test the device as specified in the manual and to
check periodically the chimney and ventilation ducts which can be the
source of carbon monoxide. The average service time of the installed
sensor is approx. 5 years from the first use of the device. After that time
the sensitivity of the sensor can decrease dramatically.
1.
Make sure the air vents in the cover are not blocked with dust or
other substances.
2.
Remove the dust from the device cover. Do not install the detector in
the locations where the humidity or dustiness are high or where the
temperature exceeds the range of working temperatures.
3.
Do not paint the device. Before painting the walls of the room where
the alarm is installed, it must be removed and reinstalled when the
paint is dry.
4.
Do not install the detector near windows, fans, heat sources, or in
locations where the leaking gas may disappear quickly.
5.
Test the device once per month.
6.
Do not repair the device on your own