background image

 

Form No. 43539500 

 

30

 

July 2021 A 

 
 
 
 

 

GAS-FIRED PRODUCTS LIMITED WARRANTY 

LIMITED WARRANTY 

Gas-Fired  Products,  Inc.  (GFP),  the  manufacturer,  warrants  the  original  owner  of  any  Space-Ray  Poultry  Heating 
Product that it will be free from defects in material or workmanship under normal use and service.  The heater(s) shall 
be  installed,  used  and  ma

intained  strictly  in  accordance  with  the  manufacturer’s  instructions.    The  manufacturer’s 

sole  obligation  under  this  warranty  is  limited  to  furnishing  replacement  parts,  F.O.B.  Charlotte,  NC,  for  12  months 
from the date of installation, or 18 months from the date of shipment by the manufacturer, whichever period expires 
first.    Labor  charges  for  the  removal  of  defective  parts  or  the  installation  of  replacement  parts  are  not  included. 
Additionally, the manufacturer will at any time during a 36 month period after installation or 42 months from the date 
of shipment by the manufacturer, whichever period expires first, furnish at no cost to the original owner, replacement 
parts for the heaters that have the model number prefix: PCA/PCS, PBF, FUS and PCA SS (Defender) tube heaters. 

ADDITIONAL  WARRANTY  ON  MODEL  SRB40,  TRU40  AND  LoPro  BROODER  EMITTERS:

  

Additionally, the manufacturer will at any time during a 36 month period after installation or 42 months from the date 
of shipment by the manufacturer, whichever period expires first, furnish at no cost to the original owner, replacement 
emitter  assemblies  or  heat  exchanger  tubes  which  have  become  inoperative  by  reason  of  any  defect  in  our 
workmanship,  materials  or  construction.    The  manufacturer  will  not  be  responsible  for  labor  charges  incurred  for 
removal or installation of emitters.  Any transportation charges involved in the return or repair are excluded. 

ADDITIONAL WARRANTY ON MODEL PCA, PBF CALORIZED TUBE HEATER HEAT EXCHANGER:

  

Additionally,  the  manufacturer  will  at  any  time  during  a  120  month  period  after  installation  or  126  months  from  the 
date  of  shipment  by  the  manufacturer,  whichever  period  expires  first,  furnish  at  no  cost  to  the  original  owner, 
replacement emitter assemblies or heat exchanger tubes which have become inoperative by reason of any defect in 
our workmanship, materials or construction.  The manufacturer will not be responsible for labor charges incurred for 
removal or installation of emitters.  Any transportation charges involved in the return or repair are excluded. 

WARNING:

  

Manufacturer’s warranty shall not apply and GFP is not responsible for damages caused with regard 

to:  (a)    circumstances  where  gas  pressure  to  each  heater  is  higher  than  that  specified  for  each  heater;  (b) 
circumstances  where  the  type  of  gas is  different  than  the  type  of  gas  noted  on  the name  plate  for  each  heater;  (c) 
water damage to gas controls; (d) circumstances where any acid or acid-based product causes damage to the metal 
components; or (e) any heater or component part which has been repaired or replaced with other than factory parts, 
modified  in  any  way,  misused  or  damaged,  or  which  has  been  used  contrary  to  the  manufacturer’s  written 
instructions. 

LIMITATION  OF  WARRANTY:

   

THERE  ARE  NO  WARRANTIES,  EXPRESS  OR  IMPLIED,  WHICH  EXTEND 

BEYOND  THE  DESCRIPTION  ON  THE  FACE  HEREOF.    WITHOUT  LIMITING  THE  FOREGOING,  THE 
MANUFACTURER  EXPRESSLY  EXCLUDES  ANY  AND  ALL  IMPLIED  WARRANTIES,  INCLUDING  BUT  NOT 
LIMITED  TO  ANY  IMPLIED  WARRANTY  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE  AND  ANY  IMPLIED 
WARRANTY OF MERCHANTABILITY FOR ITS PRODUCTS. 

If  any  provision  of  this  warranty  is  found  to  be  void,  unenforceable  or  unconscionable,  then  that  portion  is  hereby 
severed and the remainder of this warranty is hereby saved and shall remain in force. 

EXCLUSIVE  REMEDY:

   

The  sole  and  exclusive  remedy  under  this  warranty  is  the  replacement  of  the  defective 

parts or brooders as hereinabove specified.  THE MANUFACTURER DOES HEREBY EXPRESSLY EXCLUDE ANY 
AND  ALL  LIABILITY  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  UNDER  THIS  OR  ANY  OTHER 
WARRANTY.  Without intending to limit the aforesaid exclusion, THE MANUFACTURER DOES HEREBY EXCLUDE 
ANY  LIABILITY  UNDER  THIS  OR  ANY  OTHER  WARRANTY  FOR  INJURIES  OR  COMMERCIAL  LOSSES  TO 
PROPERTY THAT RESULT FROM THE OPERATION, PROPER OR IMPROPER, OF ITS PRODUCTS. 

ADDITIONAL  TERMS:

   

Manufacturer  assumes  no  liability  for  delay  in  performing  its  obligations  under  this 

warranty.    Manufacturer  assumes  no  liability  for  failure  in  performing  its  obligations  there  under  if  failure  results 
directly or indirectly from any cause beyond its control, including but not limited to acts of God, acts of Government, 
floods, fires, shortages of materials, strikes and other labor difficulties or delays or failures of transportation facilities. 

This is a Non-Residential product.  Installation and service shall be by a Licensed Contractor and in accordance with 
National and Local Codes. When presenting warranty claims, proof of date of purchase must be submitted. 

Summary of Contents for LoPro LPBH40-L5

Page 1: ...llow proper brooder operation FOR YOUR SAFETY EXHAUST FANS MUST be operating on an appropriate cycle when brooders are operating to avoid a high concentration of carbon monoxide When used without fres...

Page 2: ...is necessary because litter dust feathers and other matter can become airborne and clog openings and filters and adversely affect brooder operation and performance Every brooder should be located with...

Page 3: ...NG 25 40 7 6m 12 2m BROODER SIZE Canopy Diameter 35 890mm Brooder Height 13 75 349mm WEIGHT Assembled Brooder 21 5 lbs 10 kg VENTILATION REQUIRED Per Brooder 168 CFM 286 m3 hr GAS CONSUMPTION Propane...

Page 4: ...Environmental EW 4 20 Part No 30525010 Ratings SPDT 120 240VAC 16A Full Load Temperature range 40 Deg F to 104 Deg F 2 5 Deg F Differential Housing Watertight ABS plastic meets NEMA 4x and NEC Articl...

Page 5: ...Hose with 3 8 swivel female flare fittings and 6 spring Includes ball valve Part No 30522109 10FT Hose with 3 8 swivel female flare fittings and 6 spring Includes ball valve Kit Components Item Numbe...

Page 6: ...0257000 Minature Cable Tie 1 B Main Brooder Components Ref Part No Each Package Includes Qty 1 43303000 Reflector Canopy 1 2 43524550 Emitter Assembly with stamped cap spacers 1 3 44542250 Gas Control...

Page 7: ...er Size 7 16 Crescent Wrench 2 each STEP 1 Place the canopy over the emitter assembly and locate the 2 studs that are located above the slotted center cut out Loosely attach to the studs 2 1 4 20 hex...

Page 8: ...nd STEP 4 Flip the emitter and canopy over Align the burner with the holes in the canopy Attach the burner using 2 10 24 hex nuts STEP 5 The gas control arm comes equipped with the manifold bracket pr...

Page 9: ...nd stand off plate NOTE DO NOT COMPLETELY TIGHTEN FASTENERS AT THIS STAGE YET STEP 7 Open the swivel clamp located on the burner by carefully lifting the clamp over the latch Place the orifice fitting...

Page 10: ...as shown The control arm and burner to be in line with each other Tighten the hex nuts from STEP 6 above after any adjustments are made STEP 9 Connect the female quick connect receptacle of the ignit...

Page 11: ...N AND APPLY AT ORIFICE FITTING AND FIELD CONNECTIONS TO THE GAS VALVE 4 1 GAS VALVE WIRE CONNECTIONS STEP 1 Flip the brooder over and feed the red and blue wire leads from the gas valve through the ca...

Page 12: ...Form No 43539500 July 2021 A 11...

Page 13: ...ooder height connect each Chain Kit using a chain or cable suitable for the weight of each brooder DO NOT USE ROPE Size the winch and cable so that it is capable of handling the total weight of all br...

Page 14: ...ng for the house An example using this table is shown 2 Connect to the supply tank or manifold in accordance with the latest edition of the National Fuel Gas Code ANSI Z223 1 and or local codes Author...

Page 15: ...on method 5 Connection to a new installation with accessory hose and fittings is shown below Item Number Part Number Description Qty 1 30285000 VALVE MANUAL BALL 1 2 1 2 30241010 MALE FTG 45 FLARE 3 8...

Page 16: ...to trap impurities and water that can condense out of the gas It helps to keep impurities from entering the appliance and causing potential damage to gas valves etc Periodically remove the cap from th...

Page 17: ...ssumed leak tight If a drop in pressure does occur it indicates a leak in the system If the pressure drop occurs check the joints connectors and other possible points of leakage with an approved high...

Page 18: ...at Gas or vice versa and cannot be field adjusted for outlet manifold pressure See separate instructions for converting from one gas to another REGULATOR LOCK UP AND LEAKAGE After the leak testing and...

Page 19: ...p to 58 000 Btu hr over 200 STEP 2 Calculate the distance from the second furthest brooder to the secondary regulator In the example that distance equals 174 Using Table 1 look up the row for 174 As 1...

Page 20: ...ABLE 2 Brooder Distance from Regulator ft Flow Capacity Required Btu hr Distance Used from Table ft Smallest Pipe Size and Capacity From Table 7 and 14 202 42 000 200 58 000 6 and 13 174 84 000 200 12...

Page 21: ...comes equipped with a 375VA transformer 4 A Thermostat available as an accessory Part No 30525010 or an environmental controller etc is also required for each brooder or group of brooders as shown in...

Page 22: ...500 July 2021 A 21 B SCHEMATIC WIRING DIAGRAM Zone Control Connections Terminal Designations TH Thermostat Input GND System Ground GV1 Valve Power GV2 Valve Ground HV High Voltage Cable 1 2 3 4 Main G...

Page 23: ...ignition attempt The control will attempt two additional ignition trials before going into lockout and the valve relay will be de energized immediately 5 If the heater does not light shut off the gas...

Page 24: ...ESH AIR IMMEDIATELY Have the brooders serviced as soon as possible and check the ventilation in the house The National Fuel Gas Code requires a minimum of 4 CFM per 1000 Btu hr of brooder input for ve...

Page 25: ...anytime 25 or more of the flame turns yellow or on an annual basis we recommend that the burner and orifices be disassembled and cleaned Built up deposits in the burner will not be effectively cleane...

Page 26: ...around the burner cap ports and upper burner surfaces with a small bristle brush available as an accessory Part No 43295010 or other small wire brush After cleaning the burner ports use the same brush...

Page 27: ...table in these instructions Clean the orifice See the instructions for correct orifice size and replace if necessary Brooder will not attain the desired temperature There is insufficient heat in the b...

Page 28: ...Form No 43539500 July 2021 A 27 C TROUBLESHOOTING CHART Continued...

Page 29: ...ed Metal black paint 1 17 30632110 Ignition Module Fenwal 35 602907 015 1 18 30634433 Ignition Cable 29 1 19 30635040 Cord Connector 1 2 1 20 30635049 Locknut 1 2 1 21 30381019 Switch Rocker SPST powe...

Page 30: ...e Connections 24V 1 45 43311300 Label Nameplate Rating Plate 1 46 43311188 Label Soot Hot Surface Hazard 1 ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY WE RESERVE THE RI...

Page 31: ...ortation charges involved in the return or repair are excluded WARNING Manufacturer s warranty shall not apply and GFP is not responsible for damages caused with regard to a circumstances where gas pr...

Page 32: ...36485 Charlotte NC 28236 Phone 704 372 3488 Fax 704 332 5843 email info spaceray com FOR YOUR RECORDS Space Ray Brooder Model Number ______________________________ Date Installed ____________ Serial...