Soyal AR-327-E Manual Download Page 8

V220816

- 8 -

   

   

             

LCD Access Controller

Full Function Command Menu Table

3. Parameters [1]

4. Parameters [2]

3-3. Door Relay Tm

3-8. Arming PWD.

3-3-1

3-8-1

Main Door OpenTm
Range: 000~609
601~609=0.1~0.9
0077

Input PIN Code
Range: 0000~9999
1234

3-4. Door Close Tm

3-9. PIN&UID format

3-7. Arming Delay Tm

3-5. Alarm Relay Tm

3-6. Alarm Delay Tm

3-4-1

3-9-1

3-9-3

3-9-5

3-9-7

3-7-1

3-5-1

3-6-1

Main Door Close
delay time (Sec)
Range: 000~255
015

User PIN Length
Range: 4~8
4

Show UID   :0=No
1=WG  2=ABA  
3=HEX 4=WG26   
5=ABA8

RFID 125KHz RF
0: Disable
1: Enable
1

User Capacity:
0: 16384   1: 32768
2: 65536   (0~2)
0

Enter armed sta.
Delay time (Sec)
Range: 000~255
001

Alarm Relay Time
Range: 000~609
601~609=0.1~0.9
015

Alarm Output
Delay time (Sec)
Range: 000~255

3-2. OnOff OpenZone

3-2-1

Main Controller
Auto Open Zone
Dis/Enable (0/1)
0

3-1. Node ID

4-1. Auto Relock

4-2. Egress(R.T.E)

4-3. Miscellaneous

3-1-1

4-1-1

4-2-1

4-3-1

4-3-4

4-3-7

3-1-2

4-1-2

4-2-2

4-3-2

4-3-5

4-3-8

4-3-3

4-3-6

4-3-9

3-1-6

3-2-2

3-3-2

3-4-2

3-9-2

3-9-4

3-9-6

3-9-8

3-7-2

3-1-3

3-1-5

3-1-7

3-1-4

3-1-8

Input New NodeID
Range: 001~254
Current Data: 001

Main Controller
Auto Relock Door
0: NO   1:YES
0

Main Controller
Request TO Exit
0: Dis   1:Enable
0

Main Controller
TimeAttendance
0: YES   1: NO
0

WG1 Port
Skip PIN Check
0: NO   1: YES
0

WG1 Port
Share Main Relay
0: NO   1: YES
0

Main Door Number
Range: 000~255

WG Prot
Auto Relock Door
0: NO   1:YES
0

WG1 Port
Request TO Exit
0: Dis   1:Enable
0

WG1 Port
TimeAttendance
0: YES   1: NO
0

Main Controller
Pass any Tags
0: NO   1: YES
0

Tag Second time
interval (10ms)
Range: 0000~9999
0100

Main Controller
Skip PIN Check
0: NO   1: YES
0

WG1 Port
Pass any Tags
0: NO   1: YES
0

Max error times
for lock keypad
Range: (0~9)
5

IP Address (IPv4)
192.168.001.127
192.xxx.xxx.xxx

WG1 Port Auto Open 
Zone Dis/Enable (0/1)
0

WG1 Door OpenTm
Range: 000~609
601~609=0.1~0.9
007

WG1 Door Close
delay time (Sec)
Range: 000~255
015

Card UID Length
Range: 2~8
4

NFC 13.56MHz RF
0: Disable
1: Enable
1

'#' is Door Bell
0: Disable
1: Enable
0

Enable Buzzer
0: NO   1: YES
1

Armed Pulse out-
put time. (10ms)
Range:000~255
000

WG1 Door Number
Range: 000~255

Net Mask (IPv4)
255.255.255.000
255.xxx.xxx.xxx

Show WG Message
0: NO   1:Enable
1

Gateway (IPv4)
192.168.001.254
192.xxx.xxx.xxx

Enable DHCP
0: No   1: En   2: Exit
192.168.001.127*
0

User PIN Length Range:4~8(4 is default value)

Card PIN Length Range:2~8(4 is default value)

Summary of Contents for AR-327-E

Page 1: ...l cables to the body and attach the body to the mounting plate Assemble the covers with the Allen key and screws accessories supplied Turn on the power the LED will light and hear the beep sound you w...

Page 2: ...Duress 4 Yellow White Duress Output AR 327 E By order WireApplication Wire Color Description Lock Relay 1 Blue White N O DC24V1Amp 2 Purple White N C DC24V1Amp Lock Relay COM 3 White COM DC24V1Amp Do...

Page 3: ...8 1 5W Max 2W 1 Black DC 0V 2 Yellow TX 3 White TE 4 Orange RX 5 Red DC 5V 6 WireApplication Wire Color Description HID ProxII RF Module 1 Orange ANT 1 2 Purple ANT 2 3 Black DC 0V 4 Red DC 5V 5 Blue...

Page 4: ...AR 1207 Fire Emergency Transistor IN4007 Transistor IN4007 Transistor IN4007 Magnet Lock POWER 12VDC RTE Controller Controller Reader RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Door Contact S...

Page 5: ...B Entering and Exiting Programming Mode Changing the Master Code Access programming mode Tools Master Code Input the 6 digit new master code Succeeded 5 2 A Keyboard Lock Unlock Lock Unlock Press and...

Page 6: ...k 7 Duress Code 8 Password Mode 9 Factory Reset 3 Parameters 1 1 Node ID 2 OnOff OpenZone 3 Door Relay Tm 4 Door Close Tm 5 Alarm Relay Tm 6 Alarm Delay Tm 7 Arming Delay Tm 8 Arming PWD 9 PIN UID for...

Page 7: ...1 8 1 1 3 2 2 3 2 1 8 2 Input Start Address Range 0 16383 User Address F3 Prev F4 Next Range 0 16383 Set Site 00000 XXXXX Range 0 65535 Input End Address Range 0 16383 Is Guard User 0 NO 1 YES Set Co...

Page 8: ...254 Current Data 001 Main Controller Auto Relock Door 0 NO 1 YES 0 Main Controller Request TO Exit 0 Dis 1 Enable 0 Main Controller TimeAttendance 0 YES 1 NO 0 WG1 Port Skip PIN Check 0 NO 1 YES 0 WG...

Page 9: ...TuWeThFrSaHo 0 0 0 0 0 0 0 0 0 Lift9600 1 PRN 2 LED 3 Voice 0 YY XXXX MM XX Day XX Hour XX Min XX Sec XX F w Ver 4 4T Users 00000 Messages 00000 Press any Key 0 Lift 1 Host 2 LED 3 PRN 1 0 Suspend 1 L...

Reviews: