SOYAL
ACCESS CONTROL SYSTEM
®
AR-327-E / 727-E
V220816
- 5 -
Access programming mode
→
Add/Delete
→
Add -> RF-Learn
→
Input 5/6-digit user address
→
Input Tag Units(pcs)
→
Close Tag into RF Area
※
If adding a batch of
Sequential
tags, please input Tag Units(pcs) in the quantity of the tags and present the
tag with the
lowest card code
to the access controller.
1
2
Adding Tag by RF Learn Function
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
※
User capacity: 16384 (00000~16383)
Access programming mode
→
Add/Delete
→
Add -> Card ID
→
Input 5/6-digit user address
→
Input Site Code
→
Input Card Code
1
1
Adding Tag by Tag ID
Access programming mode
→
Add/Delete
→
Delete -> Addr
→
Input Starting address
→
Input Ending address
1
5
Deleting User Address
Access programming mode
→
User Setting
→
Access Mode
→
Input User Address
→
0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2
2
Setting up the access mode
Access programming mode
→
Add/Delete
→
Delete -> ID #
→
Input Site Code
→
Input Card Code
1
6
Deleting Tag by Tag ID
F. PIN Code
C. Initial setup
E. Duress Code
Access programming mode
→
User Setting
→
Password
→
Input
5/6-digit user address
→
Input 4-digit PIN (0001~9999)
→
Succeeded Or via
701Client set it on Users screen
2
1
Node ID of Reader Setting
Access programming mode
→
Parameters[1]
→
Node
ID
→
Input New Node ID : 1~254
(default value:001)
→
Main
Door Number : 0~255
→
WG1 Door Number : 0~255
→
Show WG Message (0=No,1=Enable)
→
Network setting
→
Succeeded
3
1
Language Setting
Access programming mode
→
Tools
→
Language
→
0 EN
→
Succeeded
→
Initial system...
5
1
H. Enable Voice Module (supporting version : F/w Ver 3.02
or later)
Software Setting 701 Server or
Programming
B. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode
→
Tools
→
Master Code
→
Input the 6-digit new master code
→
Succeeded
5
2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard.
Press again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master
Code= 876112, input
876112
→
Access programming mode
P.S.If entering no instruction within
30 sec.
, it will automatically
leave the programming mode.
Exiting
Press the repeatedly
→
Quit or Quit and Arming
(Please refer to alarm / arming setting)
6
7
G. Setting up the alarm / arming
Conditions:
1. Arming enabled 2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus door close
time.
2. Force open
(Opened without a valid user card): Access by force or illegal
procedure.
3. Door position abnormal
: When power is off and then on, reader on arming
before power off.
Step 1.
Click "Read from Controller"
Step 2.
Select "Card Reader / Voice Module" in RS485-2 section.
Step 3.
Click "Write to Controller" to finish the setting.
Hardware setting
Access programming mode
→
Tools
→
Ext. Comm Port
→
Voice
5
5
2
Adding and Deleting Tag
1
2
3
Or via 701Server to set it on AR-829E-V5 screen
※
Duress Code is only available in networking mode. It will
substitute a personal pin code and send the message of Duress
to computer as a warning signal.
※
The Duress Code 0000 means that disable Duress Function and
the default value is set as 0000 already.
Access programming mode
→
Parameters[2]
→
Duress
Code
→
4 sets (select one)
→
Input 4-digit PIN (0001~9999)
→
Succeeded
4
7
D. PIN & UID Length setting
Access programming mode
→
Parameters[1]
→
PIN & UID
format
→
User PIN Length Range:4~8(4 is default value)
;
Card PIN Length Range:2~8(4 is default value)
3