V221024
- 4 -
Access Controller
D. Setting Up the Arming
[Only for connect to external K-series reader]
M4/M8: Individual pass code
Card or PIN:
Access programming mode
→
12 UUUUU ???? [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN:
Access programming mode
→
13 UUUUU ???? [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN:
Access programming mode
→
15 ???? [Input 4-digit pass code, default value: 4321]
Card and PIN:
Access programming mode
→
17 ???? [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
B. Set up the password
[Only for connect to external K-series reader]
C. Lift control
Enable
Access programming mode
→
24 002 [002= enable lift control]
Connect with
AR-401RO16B
to control floors which the user will be able to access.
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
Multi floors
Access programming mode
→
21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
Single floor
[e.g.] User address NO. 45, allow to access the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
Set
Floor/ Stop
F
8
16
24
32
0
1
2
3
F
6
14
22
30
F
7
15
23
31
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
1.
Normal Opening
2.
Abnormal Opening
Arming Setting and Alarm Trigger Procedure :
Arming Mode
Disarming Mode
T
riggering Alarm
Condition:
T
riggering Alarm
Condition:
VS
abnormal door
position
door open to
o
long
door is for
ced
openg
door is for
ced
openg
Door Relay TM
Arming Delay TM
Enable Arming
Alarm Relay TM
Door Close TM
Alarm Delay TM
Enable
Arming Status
Alarm Trigger
Door open
Green Led Flash Quickly
Red Led Flash Quickly
Alarm trigger
Green Led Flash
Standby Mode
(Arming is not enable)
Enable
Arming Status
Alarm Trigger
Green Led Flash Quickly
Red Led Flash Quickly
Green Led Flash
Arming Delay TM
Enable Arming
Standby Mode
(Arming is not enable)
Alarm Relay TM
Alarm Delay TM
Alarm trigger
In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming
Mode. The conditions for triggering the alarm in these two modes is different, as shown in the following comparison:
Alarm conditions:
1. Door is forced open
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.
The default value of access function of M6 is Card and PIN, it will have 3 beeps for hinting you input PIN
number after card presentation. Access function modification please refer the table below:
17 ???? 15 0000
????=4-digit PIN(0001~9999 ; default value=1234)
????=4-digit PIN(0001~9999 ; default value=4321)
17 0000 15 0000
17 0000 15 ????
Card and PIN
Card only
Card or PIN
Access Mode
Command