background image

Introduction

1

The Southwire 40040S Continuity Tester provides a simple way of 

checking continuity on wires and cables. The bright LEDs and loud 

pulsating beeper provide a positive indication of continuity and polarity. 

The detachable remote indicator can be used to trace multiple cable runs. 

With proper use, this tester will provide many years of reliable service.

WARNINGS

• Read, understand and follow Safety Rules and Operating Instructions

  in this manual before using this tester.

• Do not connect the tester to a live circuit. Connecting the tester to  

  voltage presents a shock hazard and may damage the tester. 

• Do not use if the tester or test leads appear damaged or is not

  operating properly.

• Do not use the tester in a wet or damp environment or during

  electrical storms.

• Do not use the tester near explosive gases, dust or vapor.

• Replace the battery as soon as the low battery warning appears. 

Maintenance

1. KEEP THE TESTER DRY. If it gets wet, wipe it off.

2. USE AND STORE THE TESTER IN NORMAL TEMPERATURES.  

    Temperature extremes can shorten the life of the electronic parts

    and distort or melt plastic parts.

3. HANDLE THE TESTER GENTLY AND CAREFULLY. Dropping it can  

    damage the electronic parts or the case.

4. KEEP THE TESTER CLEAN. Wipe the case occasionally with a

    damp cloth. DO NOT use chemicals, cleaning solvents, or detergents.

5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND  

    TYPE. Remove old or weak batteries so they do not leak and damage  

    the unit.

6. IF THE TESTER IS TO BE STORED FOR A LONG PERIOD OF TIME,  

    the battery should be removed to prevent damage to the meter.

2

General Specifications

Beeper

Distance

Operating Temperature

Storage Temperature

Operating Humidity

Battery

Dimensions

Weight

85dB
10,000 feet (3000 meters) minimum, 26 AWG
10 to 113°F (-12 to 45°C)
-4 to 140°F (-20 to 60°C)
10 to 90% RH (non-condensing)
One 9 volt battery
5.11” x 2.05” x 1.30” (130 x 52 x 33mm)
4.5oz (129g)

Tester Description

1. Red LED continuity indicator (- Polarity)
2. Green LED continuity indicator (+ Polarity)
3. On/Off button
4. Power on LED (flashes when battery is low)
5. Detachable remote
6. Remote bi-color LED continuity

    and polarity indicator 

40040S

Continuity Tester

POWER

Tester

Remote

n/a

R

B

R

B

R

B

R

B

R

B

40040S

Remote

6.

1.

2.

3.

4.

5.

FCC COMPLIANCE

Users of this product are cautioned not to make modifications or changes that are not approved by Southwire Company, LLC. Doing so may void

the compliance of this product with applicable FCC requirements and may result in the loss of the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that can cause

undesired operation.

FCC Digital Emissions Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate

radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio

or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one

or more of the following measures:

• Reorient or relocate the radio or television receiving antenna.
• Increase the separation between the computer equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the radio or television receiver is connected.
• Consult the dealer or an experienced radio television technician for help.

Canadian Digital Apparatus Compliance

 

CAN ICES-3 (B)/NMB-3(B)
   

Summary of Contents for 40040S

Page 1: ...ls com 1 855 SW T00LS Toll Free Technical Help Línea de Ayuda Técnica Gratuita Scan for warranty information and to access our mobile site Escanea para informaciónde garantía y acceso a nuestro sitio móvil Operating Instructions 40040S Continuity Tester Instrucciones de Operación Probador de Continuidad 40040S 40040S Continuity Tester POWER Tester Remote n a R B R B R B R B R B 40040S Remote ...

Page 2: ... LED continuity indicator Polarity 2 Green LED continuity indicator Polarity 3 On Off button 4 Power on LED flashes when battery is low 5 Detachable remote 6 Remote bi color LED continuity and polarity indicator 40040S Continuity Tester POWER Tester Remote n a R B R B R B R B R B 40040S Remote 6 1 2 3 4 5 FCC COMPLIANCE Users of this product are cautioned not to make modifications or changes that ...

Page 3: ...ity Test NOTE The tester does not turn off automatically Press the button to turn the tester off after use The tester will beep twice and the LED adjacent to the button will turn off WIRE Resistance Range 0 to approx 150Ω Approx 150 to 2 9kΩ Approx 2 9k to 5 3kΩ Above approx 5 3kΩ Flashing Beeping Rate Very Fast Slow Fast No Flashing Beeping Red LED Green LED Flashing NOT Glowing 4 Operation Examp...

Page 4: ...tions in the manual for Battery Replacement 2 Loosen the 4 Phillips screws on back cover 3 Carefully remove cover while feeding the battery clip through the slot inside the battery compartment 4 Gently remove fuse and install new fuse into the holder 5 Always use a fuse of the proper size and value 100mA 250V fast blow 5 x 20mm Do not substitute 6 Install the back cover and battery cover and tight...

Page 5: ...e product Whether Southwire repairs or replaces the product will be a determination that Southwire makes at its sole discretion SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL BE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE SOUTHWIRE MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED OTHER THAN THE WARRANTY SPECIFICALLY SET FORTH HEREIN SOUTHWIRE WILL NOT BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL I...

Page 6: ...129 g Descripción del Probador 1 Indicador de continuidad con luz LED roja Polaridad 2 Indicador de continuidad con luz LED verde Polaridad 3 Botón de Encendido Apagado 4 Luz LED de encendido parpadea cuando la batería está baja 5 Remoto desmontable 6 Indicador remoto bicolor de continuidad y polaridad con luz LED 40040S Continuity Tester POWER Tester Remote n a R B R B R B R B R B 40040S Remote 6...

Page 7: ...o El probador sonará dos veces y la luz LED al lado del botón se apagará Presione el botón durante apróx un segundo El probador emitirá un sonido y la luz LED al lado del botón se iluminará para indicar que el probador está encendido Si la luz LED parpadea el voltaje de la batería es demasiado bajo para un funcionamiento fiable Consulte la sección de Reemplazo de Batería en el manual y reemplace l...

Page 8: ...lazar la batería 2 Afloje los 4 tornillos Phillips de la contraportada 3 Retire con cuidado la cubierta mientras pasa el clip de la batería a través de la ranura en el interior del compartimiento de la batería 4 Retire con cuidado el fusible e instale el fusible nuevo en el soporte 5 Siempre use un fusible del tamaño y valor apropiado fusible de acción rápida 100mA 250V 5 x 20 mm No sustituya 6 In...

Page 9: ...del producto se hará bajo la determinación de Southwire y a su discreción SOUTHWIRE NO GARANTIZA QUE ESTE PRODUCTO SERÁ COMERCIABLE O ADECUADO PARA ALGÚN PROPÓSITO EN PARTICULAR SOUTHWIRE NO HACE NINGUNA OTRA GARANTÍA EXPRESA O IMPLÍCITA SALVO QUE LA GARANTÍA ESPECÍFICAMENTE MENCIONADA EN ESTE PÁRRAFO SOUTHWIRE NO SERÁ RESPONSABLE DE DAÑOS INCIDENTALES CONSECUENCIALES INDIRECTOS ESPECIALES O PUNIT...

Reviews: