Southwire 23090T MaintenancePRO Operating Instructions Manual Download Page 20

REGISTER YOUR PRODUCT

Register your product purchase at 

www.southwiretools.com

 or by scanning 

the QR code on this manual. At Southwire, we are dedicated to providing you 

with the best customer experience. By following a few quick steps to register, 

you can experience quicker service, more efficient support, and receive 

information on our future products. Simply provide your model number,

serial number, and just a few pieces of information about yourself –

it is that quick and easy. 

LIMITED WARRANTY AND LIMITATION OF LIABILITY ON

SOUTHWIRE METERS & TESTERS

Southwire Company, LLC. warrants this product to be free from defects in 

material and workmanship for two years from the date of purchase. This 

warranty does not cover fuses, disposable batteries, or damage arising from an 

accident, neglect, misapplication, contamination, modification, improper 

maintenance or repair, operation outside of specifications, or abnormal 

handling of the product. Southwire’s sole liability, and the purchaser’s exclusive 

remedy, for any breach of this warranty is expressly limited to Southwire’s repair 

or replacement of the product. Whether Southwire repairs or replaces the 

product will be a determination that Southwire makes at its sole discretion.

SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL

BE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.

SOUTHWIRE MAKES NO OTHER WARRANTY, EXPRESSED OR

IMPLIED, OTHER THAN THE WARRANTY SPECIFICALLY SET FORTH 

HEREIN. SOUTHWIRE WILL NOT BE LIABLE FOR ANY INCIDENTAL,

CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES FOR

ANY BREACH OF THIS WARRANTY.  

This warranty is void if this product is used for rental purposes. No product 

reseller is authorized to extend any other warranty on Southwire’s behalf 

relating to this product, and no such reseller warranty will be binding on 

Southwire. If you have a warranty claim, or if the product needs to be

serviced during or after the warranty period set forth above, please contact

the Customer Service Department at 855-SWTOOLS (855-798-6657). 

The sender is responsible for all shipping, freight, insurance, and packaging 

costs associated with sending a product to Southwire. Southwire will not be 

responsible for lost or damaged products returned pursuant to this warranty.
All products returned to Southwire under this warranty should be mailed to: 

Southwire Company, LLC.

Attention: Tool Warranty Return

840 Old Bremen Road

Carrollton, GA 30117

19

Span.  Pg 1 start INTRO

Introducción

1

La Pinza Amperimétrica 23090T MaintenancePRO™ 1000A TrueRMS AC/DC con 

aplicación móvil MApp™ mide la corriente AC y DC hasta 1000A y ofrece una 

calificación

de seguridad CAT IV 600V/CAT III 1000V. Otras funciones incluyen voltaje AC y DC, 

Resistencia, Continuidad, Capacitancia, Frecuencia, Ciclo de Trabajo, Temperatura,

y Prueba de Diodo. Una linterna incorporada y un detector de voltaje sin contacto

AC proporcionan una mayor conveniencia. El 23090T transmite de forma inalámbrica los 

datos a la aplicación móvil MAppTM vía Bluetooth

®

 permitiéndole ver, guardar, organizar

y compartir registros de datos, así como tomar medidas desde una distancia segura.

Visite metersapp.southwire.com para más información sobre como descargar las 

aplicaciones móviles. Este medidor está totalmente probado y calibrado y, con el uso 

adecuado, le proveerá muchos años de servicio confiable. 

Span.

ADVERTENCIAS

• Leer, comprender y seguir las Reglas de Seguridad e Instrucciones

  de Operación en este manual antes de usar este medidor.

• Las características de seguridad del medidor pueden no proteger al

  usuario si no se utiliza de acuerdo con las instrucciones del fabricante.

• Asegúrese de que los cables de prueba están completamente insertados

  en las tomas de entrada y mantenga los dedos alejados de las puntas de

  las sondas de metal al tomar mediciones.

• Antes de cambiar de funciones utilizando el interruptor, desconecte

  siempre los cables de prueba del circuito bajo prueba.

• Utilice únicamente cables de prueba de la lista de UL con la calificación  

  adecuada en la categoría de seguridad.

• Cumpla con todas las normas de seguridad aplicables. Use equipo  

  aprobado para protección personal cuando trabaje cerca de circuitos  

  eléctricos activos - en particular respecto al potencial de arco eléctrico.

• Tenga cuidado al trabajar en o cerca de conductores no aislados o

  barras colectoras.

• Tenga cuidado en circuitos activos. Los voltajes mayores de 30 V CA RMS,  

   42 V AC peak, o 60 V DC suponen un riesgo de descarga eléctrica.

• No utilice si los cables del probador o los cables de prueba parecen

  estar dañados. 

• No utilice el probador en ambientes húmedos o mojados o durante  

  tormentas eléctricas.

• No utilice el probador cerca de vapores explosivos, polvo o gases.

• No utilice el medidor si funciona incorrectamente. La protección puede

  verse comprometida.

• No utilice el metro, mientras que la advertencia de batería baja está  

  encendida. Reemplace la batería inmediatamente.

• Verifique el funcionamiento del medidor midiendo tensión conocida.

• No aplique un voltaje que exceda los límites máximos de entrada nominal

  del probador.

Summary of Contents for 23090T MaintenancePRO

Page 1: ...ls com 1 855 SW T00LS Toll Free Technical Help L nea de Ayuda T cnica Gratuita Scan for warranty information and to access our mobile site Escanea para informaci nde garant a y acceso a nuestro sitio...

Page 2: ...este manual En Southwire estamos dedicados a proveer la mejor experiencia al cliente Al seguir unos pasos r pidos para registrar su producto usted puede recibir un servicio m s r pido ayuda m s efecti...

Page 3: ...30 minutes 9 x 3 x 1 6 230 x 76 x 40mm 0 69lb 315g Complies with UL 61010 1 3rd edition for measurement CAT IV 600V CAT lll 1000V Pollution Degree 2 span 18 40Hz a 1kHz 20 a 80 Protecci n de Entrada 1...

Page 4: ...sions Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Page 5: ...1000A Ancho de banda actual AC 50 a 60 Hz Corriente AC actual se especifica desde 5 a 100 del rango 10mA 0 1A 2 5 5 d gitos Corriente AC 500 00A 1000 0A Entrada M xima 1000A AC rms o DC 1000A 10mA 0...

Page 6: ...ater a 1 Cuando la bater a se agote el s mbolo aparecer en la pantalla LCD Reemplace la bater a inmediatamente 2 Utilice un peque o destornillador de punta plana para aflojar el tornillo 3 Retire la c...

Page 7: ...electricidad est tica y otras fuentes de energ a el ctrica pueden activar aleatoriamente el detector Esta es una operaci n normal El detector s lo activa la luz indicadora cuando el voltaje AC est pre...

Page 8: ...is applied the meter will display and hold the INRUSH current reading To return to normal operation momentarily press the PEAK INRUSH button 13 Prueba de Capacitancia 1 Coloque el interruptor de funci...

Page 9: ...does not operate on Resistance Continuity or Capacitance Bluetooth Flashlight Button Bluetooth allows readings to be displayed and stored on mobile devices To activate Bluetooth press and hold the bl...

Page 10: ...ng the MODE button In the DC mode allow time for the meter to Zero before taking a measurement If necessary press the REL Hz button to Zero out any DC offset Zeroing the meter is not necessary when me...

Page 11: ...T IV 600V CAT III 1000V 10 Mediciones de Voltaje AC DC 1 Para las mediciones de voltaje de hasta 1000V ajuste el interruptor de funci n rotativa en la posici n V Para las mediciones de 500mV o menos a...

Page 12: ...rruptor a la funci n deseada Para desactivar el apagado autom tico ajuste el interruptor de funci n en la posici n de apagado Mantenga pulsado el bot n MODE mientras ajusta el interruptor de funci n e...

Page 13: ...e o voltaje Bot n MAX MIN La funci n MAX MIN muestra las medidas m s altas y m s bajas Las lecturas se actualizan cada vez que una medici n superior o inferior es capturada Para activar presione momen...

Page 14: ...e el bot n HOLD de nuevo para volver al funcionamiento normal La luz de fondo ilumina la pantalla cuando la luz de ambiente es demasiado baja para ver las lecturas Para encender o apagar la luz de fon...

Page 15: ...G Non Contact AC Voltage Detector 110 to 1000V AC WARNING Risk of Electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation WARNING Insulation type a...

Page 16: ...r is securely fastened to the meter WARNING To avoid electric shock remove the test leads from the meter before removing the battery cover WARNINGS screw 5 Descripci n del Metro 2 1 3 6 10 12 15 9 4 5...

Page 17: ...5V 50 500 1000V 1000V AC rms or 1000V DC 0 01mV 0 1mV 1mV 10mV 0 1V 1 0 8 digits 1 5 3 digits DC mV DC Voltage Autoranging Function Range Resolution Accuracy of reading digits Mantenimiento Esta Pinz...

Page 18: ...el metro cables de pruebas y cualquier accesorio conectado al metro y cables de pruebas La combinaci n de clasificaci n es la M S BAJA de cualquier componente individual CUMPLIMIENTO CON FCC Se advier...

Page 19: ...encia Prueba de Diodo Continuidad Capacitancia Temperatura C F 1000A AC DC 1000V AC DC 600V AC DC 600V AC DC 2 CAT III 1000V CAT IV 600V CAT II 1000V Punta Aislada Encendia Punta Aislada Retirada ADVE...

Page 20: ...an Pg 1 start INTRO Introducci n 1 La Pinza Amperim trica 23090T MaintenancePRO 1000A TrueRMS AC DC con aplicaci n m vil MApp mide la corriente AC y DC hasta 1000A y ofrece una cali caci n de segurida...

Reviews: