Temperature Measurements
Operation cont.
1. Set the rotary function switch to the
°F °C
position.
2. Connect the Temperature Probe to the Banana Plug Adapter.
Note the – and + markings on the adapter.
Connect the adapter to the meter, making sure
the – side goes into the
COM
input jack and
the + side goes into the
°F °C
input jack.
3. Press the
MODE
button to select readings in
°F or °C.
4. Touch the tip of the Temperature Probe to the
object being measured. Keep the probe touching
the object until the reading stabilizes (about 30 sec).
5. Read the temperature on the LCD display.
1. The non-contact voltage detector operates when
the meter is set to any measuring function.
The detector does not operate when Auto Power Off
turns the meter off or when the rotary function switch
is set to the off position.
2. Slowly move the detector probe closer to the conductor
being tested.
3. If AC voltage within the specified range is present, the indicator light will illuminate.
To avoid electric shock, remove the temperature
probe before changing to another measurement function.
WARNING:
Non-Contact AC Voltage Detector
(110 to 1000V AC)
WARNING:
Risk of Electrocution. Before use, always
test the Voltage Detector on a known live circuit to verify proper operation.
WARNING:
Insulation type and thickness, and distance from the voltage source
and other factors may effect operation. Use other methods to verify live voltage if there
is any uncertainty.
NOTES :
The detector is designed with high sensitivity. Static electricity and other sources of
electrical energy may randomly activate the detector. This is normal operation.
The detector only activates the indicator light when AC voltage is present. It does not indicate
the voltage level on the LCD display.
WARNING:
Do not touch the temperature probe to live circuits.
Símbolos
Utilizados en
la Pantalla LCD
6
V
A
~
-
Ω
F
Hz
%
°F
°C
n
µ
m
k
M
OL
AUTO
HOLD
MAX/MIN
PMAX/PMIN
REL
INRUSH
Voltios
Amperios
Corriente Alterna
Corriente Continua
Signo de Menos
Ohmios
Bluetooth®
Continuidad
Prueba de Diodos
Faradios (capacitancia)
Hertz (frecuencia)
Porcentaje (proporción de funcionamiento)
Grados Fahrenheit
Grados Celsius
nano (10
-9
)
micro (10
-6
)
mili (10
-3
)
kilo (10
3
)
mega (10
6
)
Sobrecarga
Apagado Automático
Batería baja
Rango Automático
Retención de la Pantalla
Máximo/Mínimo
Pico Máximo/Pico Mínimo
Relativo
Corriente de Entrada