Southwire 23090T MaintenancePRO Operating Instructions Manual Download Page 15

Span.

14

Temperature Measurements

Operation cont.

1. Set the rotary function switch to the 

°F °C

 position.

2. Connect the Temperature Probe to the Banana Plug Adapter.

    Note the – and + markings on the adapter.

    Connect the adapter to the meter, making sure

    the – side goes into the 

COM

 input jack and

    the + side goes into the 

°F °C

 input jack.

3. Press the 

MODE

 button to select readings in

    °F or °C.
4. Touch the tip of the Temperature Probe to the

    object being measured. Keep the probe touching 

    the object until the reading stabilizes (about 30 sec).
5. Read the temperature on the LCD display.

1. The non-contact voltage detector operates when

    the meter is set to any measuring function.

    The detector does not operate when Auto Power Off

    turns the meter off or when the rotary function switch

    is set to the off       position.   

2. Slowly move the detector probe closer to the conductor

    being tested.  

3. If AC voltage within the specified range is present, the indicator light will illuminate.  

 

              To avoid electric shock, remove the temperature

probe before changing to another measurement function.

WARNING:

  

Non-Contact AC Voltage Detector 

(110 to 1000V AC)

WARNING:

  

 

                Risk of Electrocution. Before use, always    

test the Voltage Detector on a known live circuit to verify proper operation.

WARNING:

  

 

                Insulation type and thickness, and distance from the voltage source

and other factors may effect operation. Use other methods to verify live voltage if there

is any uncertainty.

NOTES :

 The detector is designed with high sensitivity. Static electricity and other sources of

electrical energy may randomly activate the detector. This is normal operation.

The detector only activates the indicator light when AC voltage is present. It does not indicate

the voltage level on the LCD display.   

WARNING:

  

                                Do not touch the temperature probe to live circuits. 

Símbolos

Utilizados en

la Pantalla LCD

6

V
A
~

-

Ω

 

F
Hz
%
°F
°C

µ



OL
 
 
AUTO
HOLD
MAX/MIN
PMAX/PMIN
REL

INRUSH

Voltios
Amperios
Corriente Alterna
Corriente Continua
Signo de Menos
Ohmios
Bluetooth®
Continuidad
Prueba de Diodos
Faradios (capacitancia)
Hertz (frecuencia)
Porcentaje (proporción de funcionamiento)
Grados Fahrenheit
Grados Celsius
nano (10

-9

)

micro (10

-6

)

mili (10

-3

)

kilo (10

3

)

mega (10

6

)

Sobrecarga
Apagado Automático
Batería baja
Rango Automático
Retención de la Pantalla
Máximo/Mínimo
Pico Máximo/Pico Mínimo 
Relativo
Corriente de Entrada

Summary of Contents for 23090T MaintenancePRO

Page 1: ...ls com 1 855 SW T00LS Toll Free Technical Help L nea de Ayuda T cnica Gratuita Scan for warranty information and to access our mobile site Escanea para informaci nde garant a y acceso a nuestro sitio...

Page 2: ...este manual En Southwire estamos dedicados a proveer la mejor experiencia al cliente Al seguir unos pasos r pidos para registrar su producto usted puede recibir un servicio m s r pido ayuda m s efecti...

Page 3: ...30 minutes 9 x 3 x 1 6 230 x 76 x 40mm 0 69lb 315g Complies with UL 61010 1 3rd edition for measurement CAT IV 600V CAT lll 1000V Pollution Degree 2 span 18 40Hz a 1kHz 20 a 80 Protecci n de Entrada 1...

Page 4: ...sions Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Page 5: ...1000A Ancho de banda actual AC 50 a 60 Hz Corriente AC actual se especifica desde 5 a 100 del rango 10mA 0 1A 2 5 5 d gitos Corriente AC 500 00A 1000 0A Entrada M xima 1000A AC rms o DC 1000A 10mA 0...

Page 6: ...ater a 1 Cuando la bater a se agote el s mbolo aparecer en la pantalla LCD Reemplace la bater a inmediatamente 2 Utilice un peque o destornillador de punta plana para aflojar el tornillo 3 Retire la c...

Page 7: ...electricidad est tica y otras fuentes de energ a el ctrica pueden activar aleatoriamente el detector Esta es una operaci n normal El detector s lo activa la luz indicadora cuando el voltaje AC est pre...

Page 8: ...is applied the meter will display and hold the INRUSH current reading To return to normal operation momentarily press the PEAK INRUSH button 13 Prueba de Capacitancia 1 Coloque el interruptor de funci...

Page 9: ...does not operate on Resistance Continuity or Capacitance Bluetooth Flashlight Button Bluetooth allows readings to be displayed and stored on mobile devices To activate Bluetooth press and hold the bl...

Page 10: ...ng the MODE button In the DC mode allow time for the meter to Zero before taking a measurement If necessary press the REL Hz button to Zero out any DC offset Zeroing the meter is not necessary when me...

Page 11: ...T IV 600V CAT III 1000V 10 Mediciones de Voltaje AC DC 1 Para las mediciones de voltaje de hasta 1000V ajuste el interruptor de funci n rotativa en la posici n V Para las mediciones de 500mV o menos a...

Page 12: ...rruptor a la funci n deseada Para desactivar el apagado autom tico ajuste el interruptor de funci n en la posici n de apagado Mantenga pulsado el bot n MODE mientras ajusta el interruptor de funci n e...

Page 13: ...e o voltaje Bot n MAX MIN La funci n MAX MIN muestra las medidas m s altas y m s bajas Las lecturas se actualizan cada vez que una medici n superior o inferior es capturada Para activar presione momen...

Page 14: ...e el bot n HOLD de nuevo para volver al funcionamiento normal La luz de fondo ilumina la pantalla cuando la luz de ambiente es demasiado baja para ver las lecturas Para encender o apagar la luz de fon...

Page 15: ...G Non Contact AC Voltage Detector 110 to 1000V AC WARNING Risk of Electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation WARNING Insulation type a...

Page 16: ...r is securely fastened to the meter WARNING To avoid electric shock remove the test leads from the meter before removing the battery cover WARNINGS screw 5 Descripci n del Metro 2 1 3 6 10 12 15 9 4 5...

Page 17: ...5V 50 500 1000V 1000V AC rms or 1000V DC 0 01mV 0 1mV 1mV 10mV 0 1V 1 0 8 digits 1 5 3 digits DC mV DC Voltage Autoranging Function Range Resolution Accuracy of reading digits Mantenimiento Esta Pinz...

Page 18: ...el metro cables de pruebas y cualquier accesorio conectado al metro y cables de pruebas La combinaci n de clasificaci n es la M S BAJA de cualquier componente individual CUMPLIMIENTO CON FCC Se advier...

Page 19: ...encia Prueba de Diodo Continuidad Capacitancia Temperatura C F 1000A AC DC 1000V AC DC 600V AC DC 600V AC DC 2 CAT III 1000V CAT IV 600V CAT II 1000V Punta Aislada Encendia Punta Aislada Retirada ADVE...

Page 20: ...an Pg 1 start INTRO Introducci n 1 La Pinza Amperim trica 23090T MaintenancePRO 1000A TrueRMS AC DC con aplicaci n m vil MApp mide la corriente AC y DC hasta 1000A y ofrece una cali caci n de segurida...

Reviews: