Secure the “J” bolts to the wooden template using the foundation nuts. RTemplates may
be fabricated using a single piece of plywood or using two pieces of plywood separated
by 2 x 4 in (0.6m x 1.2 m) lumber. Refer to the accompanying figures.
Note the foundation bolts MUST project above the foundation 7.0 +/- 0.38 in (18.0
cm +/- 10 mm) and be vertical and parallel to each other. These dimensions are
critical to mount the tower and for proper operation of the hinge plate.
7.0in
17.8cm
17in BOLT CIRCLE
[43.2cm]
TEMPLATE
TOP OF PIER
7.0in
17.8cm
17in BOLT CIRCLE
[43.2cm]
TOP OF PIER
2 x 4
[5 x 10]
TEMPLATE
IMPORTANT:
Do not exceed 7.0 +/- 0.38 inches (18.0 cm +/- 10 mm)
dimension or bolts may interfere with hinge plate.
TOP OF PIER
TOP OF ANCHOR BOLT
TOP OF WASHER
THESE DIMENSIONS
MUST BE OBSERVED
7.00"
(17.8cm 1)
.38
(11.1cm .3)
4.38" .12
Southwest Windpower
5
4
3
2
1
--
--
ECO#--
NC
REVISIONS
REV.
.XXX ± .002
.XX ± .05
HINGE-PIER CONNECTION
T. George
01/12/09
Flagstaff, Arizona U.S.A.
MONOPOLE TOWER
do not manually update
scale 1: 8
size A
CAD file :
dwg #
sheet 1 of 1
rev. NC
DATE
APPROVALS
DRAWN
R&D
PROD EGR
MFG
QUAL
MATERIAL:
FINISH:
DO NOT SCALE DRAWING
DWG #-------------------
CAD-generated drawing
.X ± .1 ± 30 '
decimals angles
other purpose except as specifically authorized in writing by Southwest Windpower.
APPROVED
DATE
DESCRIPTION
unless otherwise specified
dimensions are inches
tolerances are :
Proprietary rights are included in the information disclosed herein. This information is
submitted in confidence and neither the document nor the information disclosed here-
in shall be reproduced or transferred to other documents for manufacturing or for any
--