INSTALLATION AND OPERATION MANUAL,
ELECTRIC COUNTER CONVECTION STEAMER, MODELS
R24
-3,
R24
-5
MANUAL 1195730 REV0 (11/22/2011) 22 HEAVY DUTY STEAM
7.0 ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS
NOTICE: Contact the factory, the factory representative or local
service company to perform maintenance and repairs.
The steamer has been factory set so that when it is ON and in the READY mode, it will maintain
water temperature in the steam generator tank at approximately 205 degrees Fahrenheit (just
below water boiling point). However, for high altitude locations, an authorized servicer must
adjust the steamer temperature lower. To adjust:
1. Remove side panel and turn control panel power switch to ON.
2. Open compartment door, and after about 5 minutes, steam will be seen, entering the
cooking compartment.
3. Turn thermostat shaft counterclockwise to lower temperature until steam just ceases to
enter cooking compartment and READY light goes on.
4. Replace side panel.
5. Follow TESTING PROCEDURES in this manual.