T
ROUBLESHOOTING
M
ODEL
EZ-3 & EZ-5 C
OUNTERTOP
S
TEAMERS
Figure 17
Door Switch Continuity Check (for units built after January 15, 2001)
Terminal Block
Door Switch
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.
4. Remove door switch lead wires from terminal block position 1 and terminal 8 of the controller.
5. Place test lead as shown inside the terminal connectors of the lead wires.
6. Check for continuity - (there should be NO continuity).
7. Depress door switch actuator rod and check for continuity - (there should be continuity).
TROUBLESHOOTING
P
AGE
28 O
PERATOR
’
S
M
ANUAL
1178387