Page 1: ...d or electrical cooking equipment then the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed a...

Page 2: ...Operating Instructions 15 SECTION SIX SERVICE Service Information 16 SECTION SEVEN PARTS Parts List 23 SECTION EIGHT WIRING Wiring Diagrams 35 CAUTION WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE P...

Page 3: ...not be liable for consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium l...

Page 4: ...s i EC Electrical Connection 120 Volts 60 Hertz single phase with grounding wire required unless otherwise specified DR Boiler and compartment drain approx 2 in diameter Provide open air gap type dra...

Page 5: ...erate satisfactorily Therefore a Model SC 2 requires 2 BHP and a Model SC 3 requires 3 BHP Assuming availability of 30 p s i supply steam pressure immediately to the appliance then pipe sizes of 1 2 3...

Page 6: ...mately 32 p s i from an original Boiler supply of 40 p s i It is suggested that wherever possible the steam supply line to the appliance be a separate line from the steam source If the appliance must...

Page 7: ...becomes an entirely sealed chamber The duration of the cooking cycle is controlled by the Timer and when desired time has elapsed Timer will read 0 and will set off an audible Buzzer and de energize...

Page 8: ...pans since steam circulation between pans in the compartment will be impeded Always preheat compartments for satisfactory results When a11 compartments are to be used at the same time allow one compa...

Page 9: ...hell Solid 7 8 4 6 Eggs in 2 1 2 2 3 3 dozen 1 3 Shell Perforated 4 6 4 6 Fish Fillets 2 1 2 8 12 3 1 3 Perforated 10 15 4 6 Meatloaf 2 1 2 35 40 15 1 3 Solid for Broth 40 45 4 6 Peas 2 1 2 6 7 5 1 3...

Page 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 8 FIG 2...

Page 11: ...within the chamber of the Water Level Control and when it drops it will trip the switch in the control and demand sufficient water to replenish it to the proper level A MANUAL VALVE LOCATED DIRECTLY...

Page 12: ...ght is located directly above the Power Switch and when lit green indicates power is ON Item L Operating Pressure Switch is fastened to the inside bottom front of the Generator Control Box and is plum...

Page 13: ...l consequently set off this valve ONCE A WEEK THIS VALVE SHOULD BE TRIPPED DURING OPERATION TO ASSURE THAT IT FUNCTIONS PROPERLY Item R Pressure Regulator reduces the pressure of the steam supplied fr...

Page 14: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 FIG 3 12 EXHAUST TO DRAIN STEAM IN...

Page 15: ...IN ACCESS TO SCREW OPEN COMPARTMENT DOOR AND TURN HANDWHEEL CLOCKWISE CLOSE DIRECTION UNTIL GASKET RETAINING PLATE IS FULLY EXTENDED OUT OF DOOR GRASP FINGER HOOKS AND LIFT UP AND OUT TO REMOVE GASKET...

Page 16: ...TOM A stainless steel strainer is provided in each compartment just ahead of the exhaust port as a protective device for this valve Remove clean and replace if excessive food and or dirt accumulation...

Page 17: ...dwheel clockwise sufficiently to provide a good seal on gasket Set Timer to desired cooking cycle Pull out Operating Handle and set in position Pilot light will indicate that cooking cycle is now in p...

Page 18: ...turn Foreign matter or lack of lubricant on dry Thrust Screw may cause threads to bind Refer to Section 4 Periodic Maintenance If Thrust Screw is bent or threads are badly worn remove Thrust Screw and...

Page 19: ...e may be incapable of opening Since this valve contains a moveable blade and when de energized the blade reacts as a guillotine which should be free to move fully down into the valve pocket projection...

Page 20: ...et is ON and steam pressure reading shows 5 to 6 p s i on Pressure Gauge of Cooker Control Panel and all compartments fail to function for the cooking cycle then power obviously is not being supplied...

Page 21: ...thus the float is unable to trip the switch in the control to de energize the solenoid valve and consequently stop water from being fed to the Heat Exchanger and flooding the system Refer to Heat Exch...

Page 22: ...ch or slotted screwdriver will lower the pressure settings Refer to Periodic Maintenance Section 4 for proper pressure settings Each nut should be turned slightly and the pressure reading on the Gauge...

Page 23: ...efer to Heat Exchanger on Removal of Sealants etc for proper procedure Heat Exchanger achieves pressure slower than normal If the Heat Exchanger requires considerably more time than 25 minutes to achi...

Page 24: ...ight Unplug and or uncap all pipe fittings and allow solution together with sealant to drain out During the procedure exercise extreme care to avoid personally coming in contact with the acid If conta...

Page 25: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23...

Page 26: ...placement parts may be ordered either through a Southbend Authorized Parts Distributor or a South bend Authorized Service Agency When ordering parts please supply the Model Number Serial Number Part N...

Page 27: ...8 1181 Alignment Screw 2 9 1 69C0 Nut 2 10 8 1182 Thrust 8ar 1 11 8 1183 Thrust Screw 1 12 2 W186 Hasher 1 13 8 1184 Compartment Door 1 14 8 1187 Bronze Bushing 2 15 1 T6S8 Tension Pin 2 16 8 1188 Hi...

Page 28: ...PARTS LIST SECTION 7 MODELS SC 2 SC 3 COOKER ASSEMBLY FIG 5 25...

Page 29: ...03 Microswitch 2 12 1 S7C4 Miroswitch Spacer 2 13 2 11C9 Microswitch Screw 2 14 3 CV42 Compartment Vent 1 15 3 S467 Exhaust Solenoid Valve 1 16 3 2200 Brass Nipple 2 17 3 U4BE Union Elbow 2 18 3 S422...

Page 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27...

Page 31: ...nstruction Label 2 comp 1 or 8 1205 Cooker Instruction Label 3 comp 1 7 3 PG15 Pressure Gauge 1 8 3 15PG Gauge Fastening Bracket 2 9 1 39CO Pressure Gauge Nut 2 10 1 59CO Enclosure Fastening Nut 2 com...

Page 32: ...PARTS LIST SECTION 7 GENERATOR CONTROL BOX ASSEMBLY FIG 8 29...

Page 33: ...t Screw 2 3 4 70EU Ground Terminal 1 4 4 LQE7 Liquid Tite Elbow Assembly 4 5 8 1244 Control Box Cover 1 6 1 33C3 Cover Bolts 4 7 3 S162 Solenoid Valve 2 8 1 23C3 Terminal Block Screw 4 9 4 22T8 Termin...

Page 34: ...PARTS LIST SECTION 7 GENERATOR ASSEMBLY FIG 5 31...

Page 35: ...Pressure Regulator 1 4 8 1254 Steamer Drain Assembly 1 5 8 1255 Exhaust Drain Assembly 1 6 3 WG20 Water Gauge Assembly 1 7 3 TST1 Thermostatic Steam Trap 1 8 3 TST3 Thermostatic Steam Trap 1 9 3 S567...

Page 36: ...PARTS LIST SECTION 7 CABINET FIG 9 33...

Page 37: ...less Back 1 2 8 1305 Side Panel 2 3 8 1308 Flanged Adjustable Foot Rear 2 4 5 FS64 Adjustable Foot Insert Front 2 5 5 MC02 Magnetic Door Catch 2 1 11C2 Magnetic Door Catch Screws 8 6 8 1303 Right Hand...

Page 38: ...WIRING DIAGRAM MODELS SC 2 SC 3 SECTION 8 35...

Page 39: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SUPPLEMENT SECTION 9...

Page 40: ...ervice may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number s...