INSTALLATION
END TRIM MOUNTING PROCEDURE (Fig. 6)
APPLICATION:
Sectional Battery Units with Capped Manifold.
(#1072501 Black, #
1072503
Stainless Steel Left End Trim)
(#1072500 Black, #
1072502
Stainless Steel Right End Trim)
(#1073399 End Pipe Cap)
NOTE:
Sectional type units are normally shipped with requested optional end trim attached to body side.
1.
Position end trim to the underside of the front rail, tight against front and top.
2.
Using the pre-punched holes in the end trim as a guide, drill (3) 1/8" (.125 dia.) holes and secure with (3)
#8 x
1
/2
sheet
metal screws.
WARNING:
TUBULAR GAS LINES ARE LOCATED ON THE SIDES OF THE OVEN BASE UNITS BEHIND
THE END TRIM SECURING SCREW AREA. IF HOLES NEED TO BE DRILLED, CARE MUST
BE TAKEN AND INSPECTION MADE TO INSURE THAT GAS LINES ARE NOT PUNCTURED.
NOTE:
Fryers, Spreader Cabinets, Half Section Ranges and right side of Convection Oven Base Ranges are finished and do
not require fillers when installed at outer ends of batteries.
SECTIONAL RANGES
SECTION ONE — INSTALLATION
PAGE 10
Litho in U.S.A.
4-92