INSTALLATION
NOTICE: THERE MUST BE ADEQUATE CLEARANCE BETWEEN
UNITS AND COMBUSTIBLE CONSTRUCTION. CLEARANCE MUST
ALSO BE PROVIDED FOR SERVICING AND FOR OPERATION.
WARNING: ALL UNITS MUST BE INSTALLED IN SUCH A MANNER THAT THE FLOW OF
COMBUSTION AND VENTILATION AIR ARE NOT OBSTRUCTED. PROVISIONS FOR AN
ADEQUATE AIR SUPPLY MUST ALSO BE PROVIDED. DO NOT OBSTRUCT THE FRONT OF THE
UNIT AT THE TOP BY THE CONTROL PANEL, OR THE BOTTOM JUST BELOW THE OVEN
COMPARTMENT, AS COMBUSTION AIR ENTERS THROUGH THESE AREAS.
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION ARE:
MODEL TYPE
SIDES
REAR
FRY TOP
10 IN.
6 I
N
.
SPLIT TOP
6 IN. LEFT
6 I
N
.
UNIFORM TOP
8 IN. RIGHT
6 BURNER OPEN TOP
9 I
N
.
6 IN.
3 BURNER OPEN TOP
9 I
N
.
6 IN.
3 BURNER HOT TOP (REAR)
4 BURNER OPEN TOP
6 IN.
6 IN.
2 BURNER OPEN TOP
6 IN.
6 IN.
2 BURNER HOT TOP (REAR)
GRADUATED HEAT TOP
6 IN.
6 IN.
WARNING: ON UNITS WITH THE CONVECTION-TYPE OVEN, A MINIMUM CLEARANCE OF
TWO INCHES MUST BE ALLOWED BEHIND THE MOTOR AND ANY REAR NON-COMBUSTIBLE
ENCLOSURE. CARE MUST BE TAKEN TO PROVIDE ADEQUATE AIR CIRCULATION TO
PREVENT THE MOTOR FROM OVERHEATING. NO ADDITIONAL CLEARANCE FROM THE SIDES
AND BACK IS REQUIRED FOR SERVICE AS THE UNITS ARE SERVICEABLE FROM THE FRONT.
LEGS OR OPTIONAL CASTERS:
1. A set of legs or casters are packed in the unit. A threaded receptacle is fastened to the base frame at each
comer. Each leg or caster has a similar mating thread.
2. Casters with locking brake are to be installed on front of unit.
3. Raise unit sufficiently to allow legs or casters to be screwed into the receptacles. For safety, "shore up" and
support the unit with an adequate blocking arrangement strong enough to support the load.
4. Lower unit gently. Never drop or allow the unit to fall.
5. The legs or casters can be adjusted to overcome an uneven floor
6. After the unit has been leveled, tighten the lock nuts.
7. Casters are provided with a zerk fitting for lubrication.
INSTALLATION
SECTIONAL RANGES
SECTION ONE — INSTALLATION
PAGE 4