APPENDIX A: WARRANTY 

 

The  N

2

-BLAST

®

  Nitrogen  Generator    System  is  warrantied  against  any  defects  in 

workmanship  and  materials  for  12  months  (or  1000  hours)  from  the  date  of  shipment 
from South-Tek Systems, whichever comes first. The purchaser has the liability to ensure 
that the system is fully inspected upon delivery and shall contact the appropriate shipping 
company  to  make  any  claims  on  damaged  goods  due  to  transit  within  that  shipping 
company’s policies.  If the system is received with defects that are not due to shipping, a 
written claim should be submitted to South-Tek Systems within 1 week of receiving the 
shipment.  South-Tek Systems can deny all other claims at their discretion. 

 

All  warranty  work  shall  be  done  at  a  South-Tek  System  facility  or  at  a  N

2

-BLAST

®

 

Nitrogen  Generator    Authorized  Service  Center.  Only  factory  trained  and  authorized 
personnel  are  covered  under  warranty.  Any  part  that  is  returned  /  repaired  /  replaced 
under  warranty  may  be  remanufactured  or  changed  to  a  different  specification  at  the 
factory’s option.  Any work performed by  an unauthorized person/company or usage of 
non-factory parts, may void all warranties to the product.    

 

Any  item  not  manufactured  by  South-Tek  may  carry  its  own  warranty  from  its 
manufacturer  and  will  be  warrantied  by  that  manufacturer.    All  parts  that  need  to  be 
returned  should  be  announced.    Any  item(s)  that  is  returned  to  South-Tek  Systems 
without  an  RMA  number  (return  authorization  number)  may  be  denied  and  returned  to 
the sender.  Contact the factory for RMA #’s, prior to return shipment. 
 

South-Tek Systems is not liable for damages caused by normal wear and tear, water, fire, 
erosion,  corrosion,  explosion,  misuse,  oil/gas  vapors  or  unauthorized  modifications.  
South-Tek Systems is also not liable for any losses (including CO

2

), damages, or cost of 

delays,  including  incidental  or  consequential  damages.  There  are  no  warranties  or 
guarantees,  expressed  or  implied,  including  the  warranties  of  merchantability  or  fitness 
for a particular purpose or use, other than those warranties expressed herein.   

 

For Claims, contact South-Tek Systems LLC at: 

tel (919) 847-3800    fax (919) 847-0255 

Email: 

[email protected]

 

Or write to: 

South-Tek Systems, Warranty Claims, 4724 Sharpstone Lane, Raleigh, NC 27615 

Summary of Contents for N2Blast FPS-1750

Page 1: ...FPS 1750 FPS 3000 FPS 6000 Fire Protection Systems O M Manual Version 7 05 24 2016 2020 The Leader in Nitrogen Generation Technology...

Page 2: ...Revision Date Approved By Approval Date Reason 1 J Nguyen 10 13 13 A Norman 10 13 13 Initial Release 2 J Nguyen 7 5 14 A Norman 7 5 14 3 J Nguyen 8 15 14 A Norman 8 15 14 4 J Nguyen 3 6 15 A Norman 3...

Page 3: ...ectrical Requirements 10 4 3 Mounting For N2 BLAST Nitrogen Generator 10 4 4 Installation For N2 BLAST Nitrogen Generator 12 4 5 Panel Layout and Gas Connection 13 4 6 Blastoff Air Bypass setup Option...

Page 4: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 4 of 25 APPENDIX D INSTALLATION DIAGRAM 23 APPENDIX E APS INSTALLATION DIAGRAM 24...

Page 5: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 5 of 25 Notes...

Page 6: ...Staff and should be read in its entirety prior to operation Please contact your local distributor provider for any operation and maintenance first prior to contacting the manufacturer 1 3 IMPORTANT IN...

Page 7: ...ator must follow safe working practices OSHA and local health safety code regulations during the installation operation and maintenance of the unit Warning This manual must be read in its entirety to...

Page 8: ...demand The generator comes with a built in pressure switch to indicate when the nitrogen demand is needed or has been met When the pressure switch is triggered nitrogen storage tank pressure is met it...

Page 9: ...gen Generator FPS 1750 FPS 3000 FPS 6000 Specifications Nitrogen Purity 98 0 Installation Wall Mounted Display Hours Operating Standby BlastOffTM N Storage Pressure Up to 80 PSIG Cabinet Port Connecti...

Page 10: ...80 F room o Always keep the N2 BLAST Nitrogen Generator in an upright position or in box as shipped o Do not connect the AC power cable until this manual has been read completely and all connections...

Page 11: ...6 2 Install the upper mounting bracket on a sturdy wall The brackets have a 16 center to center hole set for mounting to a standard studded wall a Use hardware min to support system weight Item 2 int...

Page 12: ...ply Line coming from the air compressor to the N2 BLAST Nitrogen Generator Air Inlet 3 Connect the N2 BLAST Nitrogen Generator to the storage tank and then to the systems Air Maintenance Device s 4 On...

Page 13: ...enerator is being bypassed by the air compressor It safeguards against a maintenance technician from inadvertently leaving the air bypass open or the N2 BLAST being powered in the off position It will...

Page 14: ...sure the amber Standby light will be illuminated Once the pressure drops to the cut in pressure the nitrogen generator will start replenishing the nitrogen into the storage tank The Operating green li...

Page 15: ...be ordered with the BlastOff System Factory installed or the system can be retrofitted in the field Some rewiring is required to field install Never reset repeatedly if the BlastOff goes off daily the...

Page 16: ...002 Prior to Filter Bowl Removal Ensure the power has been disconnected from the source Air supply to the unit should also be bypassed or disconnected from the unit You can remove the top cover to th...

Page 17: ...lement by twisting clockwise HAND TIGHT ONLY 4 Before reinstallation of the filter bowl rinse out the bowl of any debris with hot water and shake dry the water out 5 Change the O ring on the top of th...

Page 18: ...tions and your quickest solution on any issues you may have 8 FAQS 8 1 POWER ISSUES If the N2 BLAST Nitrogen Generator does not have power the production and storage of nitrogen will become apparent o...

Page 19: ...en Generator and the control panel has Blast Off light illuminated on the side panel of the unit If you hear the alarm and see the red BlastOff light on it means that the system is equipped with The B...

Page 20: ...manufactured or changed to a different specification at the factory s option Any work performed by an unauthorized person company or usage of non factory parts may void all warranties to the product A...

Page 21: ...om as possible on a horizontal section of piping or where water will not collect Ensure the Tees s 90 outlet is facing up so the main of the APS runs horizontally with the FPS piping Be sure that duri...

Page 22: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 22 of 25 APPENDIX C WIRING DIAGRAM...

Page 23: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 23 of 25 APPENDIX D INSTALLATION DIAGRAM...

Page 24: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 24 of 25 APPENDIX E APS INSTALLATION DIAGRAM...

Page 25: ...N2 BLAST Nitrogen Generator FPS 1750 FPS 3000 and FPS 6000 South Tek Systems Version 7 Revision Date 5 24 16 Page 25 of 25 Last Page...

Reviews: