6.
The coalescing element can be removed by turning it
counterclockwise with your hand; then replaced with the new element
in the reverse order.
7.
Once both elements have been replaced, bowls have been cleaned
and O-rings replaced, the bowls can be screwed back into their
corresponding filter housings.
Once all the filters have been replaced, press and hold the filter reset button
on the electrical panel, an audible beep will confirm the reset. To use the Filter
Change Reset Button on the face of the controller, the controller must be
unlocked (press and hold Mode button to lock and unlock). Put the front
cover back on the cabinet and power the unit back on. Once powered up, you
should hear the air compressor turn on, the FPS-650 and FPS-1250 will be
producing nitrogen. Be sure to check the filter bowls for leaks.
Figure 9: Filter Reset Button