xxxxxxxx
New password, must be 8 characters either printable
or non-printable. Dollar ($) sign is an invalid password
character.
$
Command terminator.
In order to set a new password the current password must first be sent.
Caution:
Errors made in sending the new password command could lead to
setting it to an unknown value. If the Password is unknown the printer must be
returned to Source Technologies to be reset to PASSWORD.
Activate/Set Front Panel Combination Lock
&%STSxxxxxxxx$
(optional)
&%STS
Lead in sequence
xxxxxxxx
Eight digit sequence, valid characters 0-9
$
Command terminator
This command sets and activates the front panel MICR combination lock. If this feature
is activated, MICR mode cannot be entered until the front panel combination is entered
correctly. All MICR features will be inaccessible until this combination is entered.
Sending an &%STS command and eight zeros deactivates the security lock.
Caution:
If the front panel combination is set and then forgotten, the printer must
be returned to Source Technologies for the combination to be deactivated.
Print MICR E-13B Font
&%SMDddd...ddd$
&%SMD
Lead in sequence
ddd...ddd
Data to be printed in E-13B MICR font
$
Command terminator
This command prints the specified data in the E-13B MICR font which is used in the
United States, Canada and Mexico. The correct spacing begins at the cursor position
modified by the MICRpoint adjustment setting at the start of the command. After the
terminator is sent, the printer is returned to its default font. After each Print E-13B
command, the MICR count is decremented by one. Upon receiving this command the
printer will verify that a MICR toner cartridge is installed and set the copies parameter to
1. See Appendix A for MICR E-13B font character mapping.
MICR Features | 5
Source Technologies, LLC ST9720 Secure MICR Printer User’s Guide