Installer Setup -
Automated Demand Response
37
ADR
(setup step 73)
Controls whether you want the thermostat to possibly respond to
signals from the utility provider. Select ON to allow this and to have
steps 74-80 appear.
ADR Action
(setup step 74)
Allows the user to determine what action is taken when an ADR
event is received.
Observe Setpoint Offsets – will offset the heat and cool setpoints by
the amounts specified in setup steps 79 and 80
Observe Static Setpoints – will set the heat and cool setpoints to the
values specified in setup steps 77 and 78
Event Max Cool Setpoint
(setup step 75)
Event Min Heat Setpoint
(setup step 76)
Specifies the range of allowable setpoint adjustments to be enforced
when any ADR signal has been received from the utility. Since
you might be paying more for energy while an event is active, you
can impose tighter limits on setpoint ranges that are only enforced
during the event.
Static Cool Setpoint
(setup step 77)
Static Heat Setpoint
(setup step 78)
Specifies the setpoints that will come into use during an event when
the ADR ACTION is set to OBSERVE STATIC SETPOINTS