33
Installer Setup -
Automated Demand Response
Static Cool Setpoint
(setup step 56)
Static Heat Setpoint
(setup step 57)
Specifies the setpoints that will come into use during an event
when the ADR ACTION is set to OBSERVE STATIC SETPOINTS
Cool Setpoint Offset
(setup step 58)
Heat Setpoint Offset
(setup step 59)
Specifies how much the current setpoints in effect prior to an
event will be altered during an event when the ADR ACTION is
set to OBSERVE SETPOINT OFFSETS. The heat setpoint can be
automatically lowered by -1 to -15 degrees while the cool setpoint
can be automatically raised by 1 to 15 degrees
DISPLAY INDICATIONS WHEN AN ADR EVENT IS HAPPENING
After setting your desired values for use during an ADR event, the
scrolling display will give a little information when an event is
pending or active. For instance, when an ADR event has been sent
to your thermostat, you might see ADR STARTS 8/14 at 2:00pm
to notify you of a pending event. Once active, you might see ADR
STOPS 8/14 at 6:00pm. When an event is active, you can press
any of COOLER, WARMER or MODE buttons, followed by the
WARMER to opt out of the event.