11
ENGLISH
ZEPHIRO 1500 LOW fog User manual
diately. The room for cooling should be at least 30cm. Keep far away from children,
fire, explosive and flammable things, and avoid scalding.
f
In the first time use, some water might spray out. This is normal.
f
When liquid is getting low, please add it again in time. If the fog machine works
without fluid for a long time, its pump and other parts could get damaged. When
adding fluid, remember to turn power off, and carefully avoid spilling over to cause
short circuits.
f
The fog machine should work under professional operator’s supervision, please do
not add flammable liquids, gas or perfume into the fog fluid tank.
f
When working, do not touch the machine and power cord.
f
When you don’t use the machine for long time or after use, please disconnect
power or unplug the power cord.
f
After using, please wipe out the liquid in the tank, as it would avoid the housing to
be corroded.
f
After use, drain the water from the machine’s icebox using the special tap.
f
All fog machines will have condensation or moisture around the nozzle.
f
All fog machines are used to emit a small amount of smoke during or after use.
f
All fog machines have heating-cooling cycles. When internal temperature drops to
minimum, the pump automatically turns on and begins heating. Once heating is
complete, the machine starts to spray smoke again.
All fog machines may set off Smoke Alarms
10. ROUTINE MAINTENANCE AND COMMON FAULTS
Periodically clean your machine to reduce replacement parts and repair ex-
penses.
f
Poor fog liquid can cause blockage. It is recommended to use high quality fog
liquid.
f
The machine might get blocked due to high concentration fluid, not-pure fluid or
overheat, so regular care and maintenance can ensure long-term use. After about
40 hours continue use, please prepare an 80% distilled water and 20% white vine-
gar blend to remove any accumulated impurities inside boiler and pipe, as follow-
ing:
1.
Wash the pipe in the tank and its filter head.
2. Pour out any liquid inside, and replace with the cleaning liquid (80% distilled
water and 20% white vinegar), turn on power, keep it operating till the clean-
ing liquid runs out.
f
If the fog turns less, and the pump makes noise, switch off the unit immediately
and check fluid level, fuse, controller interface and power plug. If all of these are
normal, please connect power again. If problems still continue, please contact the