SD RLC / REGULAGEM DO GANHO
POWER
CLIP
LEVEL
SD REMOTE
LEVEL CONTROL*
EXTERNAL LEVEL CONTROL - SD RLC (*NOT INCLUDED)
The SD RLC is an easy-to-install external level
control accessory that allows you to tune the
level of SOUNDIGITAL amplifiers that have
remote level control.
In SD RLC, you can adjust the amplifier level
without having to lean over and adjust the gain
setting on the amplifier and can monitor the
“CLIP” LED which is also available on the
accessory.
MODEL
POWER
OUTPUT
VOLTAGE
1 / 3000W
Ω
2 / 3000W
Ω
54,8 V
77,5 V
4 / 3000W
Ω
109,5 V
1
Ω
3000.1
2
Ω
3000.1
4
Ω
3000.1
11
GAIN SETTING
Necessary equipament:
Ø
Digital AC voltmeter;
Ø
Media with sine wave test tone 60Hz
recorded at 0db;
Ø
Set up procedure
This procedure is the same for both
Ø
gain controls;
Ø
Turn the gain control all the way down;
Ø
Disconnect the output cables from the
amplifier outputs;
Ø
Turn off all processing (bass, treble,
loudness, EQ, etc.);
Ø
Set the source unit volume to 3/4 of full
volume;
Ø
On the CD player,
set the fader control to
center position;
Ø
Set the LP selector switch in "OFF";
Ø
Use a 60Hz sine wave;
Ø
Connect the AC voltmeter to the
speaker output connectors of the
amplifier. Make sure you test the
voltage at the correct connectors
(+ and –);
Ø
Increase the gain control until the target
voltage is observed with the voltmeter
(see the chart below);
Ø
Once you have adjusted the amplifier
to its correct voltage output, turn off the
s o u r c e u n i t a n d r e c o n n e c t t h e
speaker(s).
D o w n l o a d t h e t r a c k s f o r s e t u p i n
https://soundigitalusa.com/tracks-for-
set-up/
Summary of Contents for 3000.1 EVO 5 1
Page 1: ...3000 1 OWNER S MANUAL...
Page 14: ...CODE 1000750329 001 AUG2022...