background image

Designed, Engineered and Made in Canada.

Instructions for the SOTA Bio Tuner, Model BT5pro

• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are 

they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units has not been 

approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA 

Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada • 

 
© 2008 SOTA Instruments Inc.  

                    Page 7 of 7  

                                       

www.sota.com

Drink plenty of water: 

It’s important to drink enough water when using the unit. 

Drinking ozonated water is especially helpful.

Stop Gradually: 

Reduce the amount of time each day for the last week of use.

ELECTRICAL SPECIFICATIONS

POWER REQUIREMENTS

Use a 9–Volt Alkaline battery for proper operation.

OPTIONAL POWER INPUT

The Bio Tuner can also be operated using NiMH rechargeable batteries. When 

purchasing rechargeable batteries, it is suggested to take the unit with you to 

ensure the batteries will fit the enclosure. 

OUTPUT SPECIFICATIONS

Maximum <1.5mA Peak ~40 Volts Peak-Peak into typical 4k ohm load. Minimum 

<~10uA, 10 Volt Peak-Peak at lowest setting. Output impedance ~20k ohm.
1,000 Hz (+/- 1%) pulse-modulated by 111.11 Hz (+/- 1%). Waveforms are Quartz 

Crystal-Controlled for precise frequency output. There is also a broad range of 

harmonic frequencies delivered in each pulse as observed on a frequency domain 

spectrum analyzer.
Pulses are an alternating current (AC) output with no direct current (DC) or offset 

bias. Output is transformer coupled so that no DC can appear at electrodes.

REPLACEMENT ACCESSORIES

To replace your accessories, contact your supplier. 

WARRANTY

The Bio Tuner is covered by a three (3) year limted warranty. Please keep proof 

of purchase. Warranty is void if the failure is due to abuse or negligence. SOTA 

reserves the right to make changes to the Bio Tuner without obligation. 

REPAIRS 

Please contact your supplier for return instructions. Or, for information about your 

closest repair depot, contact [email protected] or

Toll-Free: 1.800.224.0242 (Canada & USA)   Tel: 1.250.770.2023   

Summary of Contents for BT5PRO

Page 1: ...lth condition Results using the SOTA Products will vary for each person Please note that all purchases of SOTA Products are deemed to be made in Penticton BC Canada 2008 SOTA Instruments Inc Page 1 of 7 www sota com CONTENTS WELCOME TO SOTA 2 BEFORE USING 2 LEARN MORE 2 COMPLETE UNIT INCLUDES 2 DO NOT USE 3 CAUTIONS 3 SUMMARY OF LIGHTS 4 HOW TO USE THE BIO TUNER 4 Conductive Pads Option 4 Ear Clip...

Page 2: ...mitment to healthy lifestyle choices is an important factor in the journey to Wellness The SOTA Bio Tuner supports the mind body connection It outputs a broad range of harmonic frequencies helping to create an inner sense of calm balance and tranquility The Bio Tuner is designed to be used independently but can also be used together with any of the SOTA Products With proper care your Bio Tuner sho...

Page 3: ...afety has not been explored a In the case of pregnancy b With an implanted device such as a pacemaker etc 3 Discontinue use if a You experience headaches or pain when using the unit b You experience a ringing in your ears when using the unit c You experience an increase in neuropathy related nerve pain when using the unit 4 As with all electrical products do not use near water when driving a car o...

Page 4: ...sonably be foreseen Therefore your use of the SOTA Products constitutes your agreement that you are responsible for your decision to use the technology SUMMARY OF LIGHTS GREEN Indicates the Bio Tuner is in operation and the current is flowing through the Conductive Pads RED Indicates the battery is low and will soon need replacing HOW TO USE THE BIO TUNER 1 Place the 9 Volt Alkaline battery in the...

Page 5: ...he ON OFF switch clockwise The GREEN light on the end panel will begin to flash alternately once every second If the lights do not come on the battery may not be properly connected 4 Gradually turn up the intensity to a comfortable level The intensity should be comfortable See How It Should Feel on page 5 5 Place the unit in a pocket 6 After the 20 minute timed session the unit will automatically ...

Page 6: ...r lobes c Clean the Conductive Rubber Electrodes d Replace the Ear Clips 2 With repeated use the buzzing sensation may not be felt as much The intensity may be turned up if desired 3 You may feel a sensation on one side more than the other 4 In rare instances some individuals may not feel the current TYPICAL USE Length of Session One cycle is timed for approximately 20 minutes One session can be 2...

Page 7: ...d using NiMH rechargeable batteries When purchasing rechargeable batteries it is suggested to take the unit with you to ensure the batteries will fit the enclosure OUTPUT SPECIFICATIONS Maximum 1 5mA Peak 40 Volts Peak Peak into typical 4k ohm load Minimum 10uA 10 Volt Peak Peak at lowest setting Output impedance 20k ohm 1 000 Hz 1 pulse modulated by 111 11 Hz 1 Waveforms are Quartz Crystal Contro...