GB / 16
17 / GB
MANUAL APPLIES TO
SoRoTo 200L and 300L
APPLICATION
The SoRoTo Forced Action Mixers are ideal for mixing all kinds of mate-
rials used in the building industry, as well as mixing tasks where high
demand are required.
When mixing materials containing aggregates, we recommend using
the SoRoTo mixer arms with rubber blades.
BEFORE USE
Before starting the mixer, the telescopic legs must be positioned for the
right height for draining into a bucket or wheelbarrow.
The easiest way for adjusting the legs, is to lay the mixer down, so it
rests on all four wheels. The legs are released and locked with the fit
-
ted lock splits/bolts.
BEFORE CONNECTING TO POWER SUPPLY
Before the power is connected, the mixer arms must be set in place,
and the lid must be closed.The safety grid in front of the mixer gate
must be attached at all times.
For own safety always follow the instruction listed above before use.
OPERATING THE SoRoTo FORCED ACTION MIXER
The motor protection unit in this mixer is equipped with a bult in re-
verse locking system. This prevents the motor from running in reverse.
If the extension lead does not have a neutral (i.e. 4 core cable) the
machine will not start.
So, before you start mixing please do as follows,
1) Push the green START button
2) Notice if the mixer arms run clockwise
3) In the event that the mixer arms run counterclockwise, please
adjust to clockwise direction by following these instructions:
• It is essential the neutral wire is part of the cable (5 core) as
well as the electric socket supplying power to the motor
(i.e. wall wall socket, switchboard)
• The phases of the reverse locking system may be easily
adjusted by inserting a flatheaded screwdriver into the
slot on the red plug and turning 180 degrees
NOTE
The mixer remains non-operational if the lid is open.
Close the lid and lock it into place using the rubber strap. Start the
mixer by pressing the green START button on the protective motor
switch. Pour the required material into the drum and add liquid.
The protective motor switch has a zero voltage releaser. In case of
power failure, the mixer must be restarted. For safety reasons, the
mixer will not start if the lid is open.
NOTE
Never put your hand or any object into the machine when the power
is connected.
When the material has reached the desired consistency and the
mixing motion is finished, the mixer drum is emptied by opening the
mixer gate. The drum should be emptied right after mixing. Please
observe that the material may set in the mixer drum if left too long.