Operation 

Note:  In  delivery  condition,  the  cylinder  can  be  opened  by  every 
finger  or  remote  control.  Only  after  teaching  in  an  administrator 
finger, triggering an opening action is limited to authorised fingers 
or remote controls.  
Note: The buttons „Set“ and „Reset“ have to be pressed by using the 
supplied needle.  
Note:  Before  the  fingerprint  sensor  can  be  used,  the  button 

 

has to be pressed. However, this does not apply to the settings with 
“Set”. 
 

1.

 

Add administrator finger 

 

Press “Set” twice or until “Add Admin FP” is shown and wait ~5 
seconds. 

 

Put your finger three times on the fingerprint sensor. 

There  can  be  up  to  3  administrator  fingers  at  the  same  time.  All 
following  fingers  after  the  first  administrator  finger,  have  to  be 
acknowledged by the first one.  
 
Note: If you taught in an administrator finger, you have to place the 
administrator finger on the fingerprint sensor for all operations. 
 

2.

 

Add user finger 

 

Press “Set” three times  or until “Add  User FP” is shown and 
wait ~5 seconds. 

 

Place administrator finger 

 

Put the user finger three times on the fingerprint sensor. 

 

Please make a note of the ID of the currently added finger. This 
ID is of help if you want to delete this finger. 
 

3.

 

Delete user finger 

 

Press “Set” four times or until “Delete Single FP” is shown and 
wait ~5 seconds. 

 

Place administrator finger 

 

Use “Set” to select the user who is going to be deleted. Confirm 
by pressing 

. After 2 seconds of idling, the cylinder exits 

the delete user mode and returns to standard operation. 
 

4.

 

Delete all user finger 

 

Press “Set” five times or until “Clear all User FPs” is shown and 
wait ~5 seconds. 

 

Place administrator finger 

 

5.

 

Add remote control 

 

Press “Set” six times or until “Add Remote” is shown and wait 
~5 seconds. 

 

Place administrator finger 

 

Press a button on the remote control within 60 seconds. 

There can be up to 8 remote controls at the same time.  
 

6.

 

Delete all remote controls 

 

Press „Set” seven times or until  “Clear all Remote” is shown 
and wait ~5 seconds. 

 

Place administrator finger 
 

7.

 

Add a main RC 

 

This is an extension that has not been published yet. Please do 
not use this option. 

8.

 

Delete the main RC 

 

This is an extension that has not been published yet. Please do 
not use this option. 
 

9.

 

Language settings 

 

Press “Set” ten times or until Chinese text is shown and wait 
~5 seconds. 

 

Place administrator finger 
 

10.

 

Lock Time settings 

 

Press “Set” eleven times or until “Set Lock Time” is shown and 
wait ~5 seconds. 

 

Place administrator finger 

 

Press  “Set”  button  to  alter  the  lock  time  in  1-second 
increments.  

 

You can set the time to a minimum of five and a maximum of 
14 seconds. 

In delivery condition, the lock time is configured to 8 seconds.  
 

11.

 

Turn on Bluetooth 

 

This feature is not supported due to security reasons. Please 
do not use this option. 

 

12.

 

Reset cylinder to delivery condition 

 

Press  “Set”  thirteen  times  or  until  “Restore  to  Init  State”  is 
shown and wait ~5 seconds. 

 

Place administrator finger 

All  previously  taught  in  remote  controls,  administrator-,  and  user 
fingers have been deleted now. 
 

13.

 

Firmware and Hardware 

 

Press  “Set”  fourteen  times  or  until  “PCBA  VER  FW  VER”  is 
shown and wait ~5 seconds. 

Here  you  can  see  some  information  about  the  firmware  and 
hardware. 

 

14.

 

Aging Test 

 

Press  “Set”  fifteen  times  or  until  “Aging  Test”  is  shown  and 
wait ~5 seconds. 

This option executes a test to determine how much battery power 
is consumed by every opening or locking procedure. 
This test does not stop on its own and must be aborted by using the 
“Reset” button (The button on the other side of the “Set” button). 
Note: You can only execute an aging test if there is no admin finger. 

Summary of Contents for FLEX Fingerprint

Page 1: ...SOREX FLEX Fingerprint Zylinder f r Fern ffnung Cylinder for remote opening Bedienungsanleitung User Manual...

Page 2: ...pyright November 2020 SOREX wireless Solutions GmbH Technologie und Forschungszentrum WN Viktor Kaplan Stra e 2B A 2700 Wiener Neustadt sterreich T 43 2622 320130 F 43 2622 3201315 office sorex eu w w...

Page 3: ...ien 1 Bedienungsanleitung 2 Technische Daten 2 Bedienung 3 Schritt f r Schritt Montage 4 Fernbedienung Funkschalter anlernen 7 English Return Policy 8 Instruction manual 9 Technical Data 9 Operation 1...

Page 4: ...atorfinger zur cksetzen Wir bitten Sie daher das Produkt folgenderma en zur ckzusetzen Zylinder auf Auslieferungszustand zur cksetzen Set Knopf dreizehnmal bet tigen bzw bis Restore to Init State ersc...

Page 5: ...chts drehen damit die Blockierung des Zylinders wieder aufgehoben wird Technische Daten Produktdaten T rdicke 70mm 110mm Versorgung 3xAAA Batterie Betriebstemperatur 40 C 80 C Speicher 999 Benutzer 10...

Page 6: ...en bzw bis Add Remote erscheint und 5 Sekunden warten Best tigung durch Administrator finger Taste auf der Fernbedienung innerhalb von 60 Sekunden bet tigen Zylinder gibt positive R ckmeldung Es k nne...

Page 7: ...nen Sie die kleine Schraube der Metallh lse l sen und die H lse vorsichtig abziehen 3 Schritt Schwarzen Batteriedeckel entfernen Sie k nnen den schwarzen Batteriedeckel entfernen indem Sie den Deckel...

Page 8: ...r Bevor Sie mit der Montage starten k nnen m ssen Sie Ihren alten Zylinder entfernen Daf r m ssen Sie die Zentrierschraube ersichtlich im roten Kreis entfernen Danach k nnen Sie den alten Zylinder dur...

Page 9: ...ariieren und bitte Schraube festziehen Wenn Sie damit fertig sind k nnen Sie die drei AAA Batterien einlegen und den schwarzen Batteriedeckel sowie die Metallh lse mit der kleinen Schraube mittels Sch...

Page 10: ...n gehen Sie wie folgt vor 1 Set Knopf Abbildung 2 mit dem mitgelieferten Pin zweimal bet tigen und 5s warten 2 Finger dreimal auf den Fingerabdruck Sensor legen Sind bereits einer oder mehrere Adminis...

Page 11: ...delete all admin fingers by ourselves Therefor we would ask you to reset the cylinder like follows Reset cylinder Press Set button thirteen times until it says Restore to Init State on the display The...

Page 12: ...resolve the jam up Technical Data Product properties Door thickness 70mm 110mm Power supply 3xAAA Battery Operating temperature 40 C 80 C Storage 999 user 10 remote controls Battery life 1 year Weigh...

Page 13: ...mote is shown and wait 5 seconds Place administrator finger Press a button on the remote control within 60 seconds There can be up to 8 remote controls at the same time 6 Delete all remote controls Pr...

Page 14: ...the small screw with the enclosed screwdriver and remove the metal sleeve cautiously 3 Step Remove the battery cover You can now remove the black battery cover by gently pressing down the cover and pu...

Page 15: ...with the installation you need to remove the old cylinder To do so remove the screw inside the red circle as shown in the first picture below After doing so you re able to pull out the old cylinder as...

Page 16: ...th with the screwdriver and tighten the screw afterwards Insert the three AAA batteries put on the battery cover attach the metal sleeve and screw in the small screw to fix the sleeve 8 Step Attach th...

Page 17: ...taught in To teach in an administrator finger proceed as follows 1 Press Set button see image 2 twice with the supplied pin and wait 5 seconds 2 Put your finger three times on the fingerprint sensor...

Page 18: ......

Page 19: ...pyright November 2020 SOREX wireless Solutions GmbH Technologie und Forschungszentrum WN Viktor Kaplan Stra e 2B A 2700 Wiener Neustadt sterreich T 43 2622 320130 F 43 2622 3201315 office sorex eu w w...

Page 20: ...2020 SOREX wireless Solutions...

Reviews: