34
5. Operating
modes
In menu “5. Operating modes” the control-
ler can either be placed in automatic mode,
switched off, or placed in a manual operat-
ing mode.
The menu is closed by pressing “esc” or
selecting “Exit operating modes”.
5.2 Manual
Automatic mode is the normal operating mode of the controller. Only automatic mode
provides proper controller function taking into account the current temperatures and the
parameters that have been set! After an interruption of the mains voltage the controller
automatically returns to the last operating mode selected!
5.1 Automatic
Operating modes
The relay and thus the connected consumer are switched on and off by pressing a key,
with no regard to the current temperatures and the parameters which have been set. The
measured temperatures are also shown to provide an overview and function control.
5.3 Off
5.4 Fill system
When the operating mode “Off” is activated, all controller functions are switched
off. This can lead, for example, to overheating on the solar collector or other
system components. The measured temperatures continue to be shown to
provide an overview.
This special operating mode is intended only for the fi lling procedure for a
special “Drain Master System” with a fi ll level contact parallel to collector
sensor S1. The instructions on the display must be followed when fi lling
the system. Be sure to terminate the function when fi nished!
Caution
Danger
When operating mode “Manual” is activated, the current temperatures and
the selected parameters are no longer considered. There is a danger of
scalding or serious damage to the system. The operating mode “Manual”
may only be used by specialists for brief function tests or during commis-
sioning!
Caution