SAFETY INSTRUCTIONS

EG-Conformity

By affixing the CE mark to the unit the manufacturer declares that °CALEON Thermostat conforms to the following relevant safety regulations:

l

EU low voltage directive 2014/35/EU

l

EU electromagnetic compatibility directive 2014/30/EU

conforms. Conformity has been verified and the corresponding documentation and the EU declaration of conformity are kept on file by the man-
ufacturer.

General instructions

Please read carefully!
These installation and operating instructions contain basic instructions and important information regarding safety, installation, commissioning,
maintenance and the optimal use of the unit. Therefore these instructions must be read and understood completely by the installation
technician/specialist and by the system user before installation, commissioning and operation of the unit.

This unit is an automatic, electrical °CALEON Roomthermostat. Install the device only in dry rooms and under environmental conditions as described
under "Technical Data".

In addition, observe the applicable accident prevention regulations, the regulations of the Association of Electrical Engineering, the local power sup-
ply utility, the applicable DIN-EN standards and the installation and operating instructions for the additional system components. Installation, elec-
trical connection, commissioning and maintenance of the unit may only be carried out by specialists who possess the appropriate training.
Users: Make sure that the specialist gives you detailed information on the function and operation of the unit. Always keep these
instructions in the vicinity of the unit.

The manufacturer does not take over any liability for damage caused through improper usage or non-compliance of this manual!

Changes to the Unit

l

Changes, additions to or conversion of the unit are not permitted without written permission from the manufacturer.

l

It is likewise forbidden to install additional components that have not been tested together with the unit.

l

If it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the housing, turn the

Unit off immediately.

l

Any parts of the unit or accessories that are not in perfect condition must be exchanged immediately.

l

Use only original spare parts and accessories from the manufacturer.

l

Markings made on the unit at the factory must not be altered, removed or made illegible.

l

Only the settings described in these instructions may be set using the Unit.

Changes to the unit can compromise the safety and function of the unit or the entire system.

Warranty and Liability

The Unit has been manufactured and tested with regard to high quality and safety requirements. The warranty and liability shall not include, how-
ever, any injury to persons or material damage that is attributable to one or more of the following causes:

l

Failure to observe these installation and operating instructions.

l

Improper installation, commissioning, maintenance and operation.

l

Improperly executed repairs.

l

Unauthorized structural changes to the unit.

l

Use of the device for other than its intended purpose.

l

Operation above or below the limit values listed in the ‚Specifications‘ section.

l

Force majeure.

Disposal and Pollutants

The unit conforms to the European RoHS 2011/65/EU for the restriction of the use of certain hazardous substances in electrical and electronic equip-
ment.

Under no circumstances may the device be disposed of with the normal household waste. Dispose of the unit only at appro-
priate collection points or ship it back to the seller or manufacturer.

3

Summary of Contents for CALEON

Page 1: ...Installation and operating instruction CALEON Thermostat Read carefully before installation commissioning and operation ...

Page 2: ...ts 3 Description CALEON Thermostat 4 Specifications 4 Scopeof supply 4 Installation 5 CALEON Installation 5 Samplewiring 6 Setup 6 Setup procedure 6 Operation 7 Overview of temperatures humidity 7 Select Operating Mode 7 MainMenu 7 Expert Menu 8 Expert MenuSettings 8 SettingsFunctions 9 Set OperationHours 10 Set OperationHours 10 2 ...

Page 3: ...ty for damagecaused throughimproper usageor non complianceof thismanual Changes to the Unit l Changes additionstoor conversionof theunit arenot permitted without writtenpermissionfrom themanufacturer l It islikewiseforbiddentoinstalladditionalcomponentsthat havenot beentested together withtheunit l If it becomesclear that safeoperationof theunit isnolonger possible for examplebecauseof damagetothe...

Page 4: ...issible Ambient Conditions during operation 0 C 50 C nomoisturecondensationpermitted for transport storage 0 C 60 C nomoisturecondensationpermitted Measuring range Outsidethemeasuring rangestherearelarger deviations Internaltemperaturesensor 0 C 60 C Accuracy 1 C Resolution0 1 C Internalsensor for rel humidity 0 100 Accuracy 6 C Resolution0 1 1 Wiretemperaturesensors Optional without function Othe...

Page 5: ...e g radi atorsand windowsmust beavoided Strip cablesby 75mm max and strip thelast 7 10mm of thewires Unscrew thescrew removethecable cover and connect theelectricas described Only mainsvoltage no SELV Refit thebaseand fastenwithscrew Switchonmainsvoltageand place CALEON inoperation Thecommissioning canbe accessed inthe CALEON menuunder Expert at any time 5 ...

Page 6: ...nstall device Installthedeviceasdescribed see Samplewiring onpage6 Set Functions Assigna switching output totherespectivefunctionvia the Expert menuinthe Settings menuitem under Functions and parameterizeit see Set tingsFunctions onpage9 6 ...

Page 7: ...ystheselected location room Minus Plus Changethetarget temperature 0 5 C Main menu Navigatetothemainmenu Operating modes Specifieswhichoperating mode Normal Comfort Ecoand Off isselected Theselec ted modeisshownincolor By pressing the plusand minuskeysit ispossibletoadjust thesetpoint temperatureof themodes Main Menu Overview Operating Mode Main Menu Periods Adjustment of individualheating times f...

Page 8: ...rvice values Informationabout thedeviceversionand mes sagessuchasrestarts Factory Settings Thefactory settingsarerestored inthedevice Expert Menu Settings Overview Operating Mode Main Menu Expert Settings Functions Management of localcontrolfunctions Thermostat and dehumidifier Location Set wherethedeviceisinstalled selectionof theroom icon Sensor calibration Used toadapt thetemperatureand humid i...

Page 9: ...ing output of thefunction Hysteresis Heating hysteresis of thethermostat functioninrelationtothe actualset room temperature Dehumidifier Output Switching output of thefunction Humidity Setpoint of humidity Hysteresis Hysteresisof thedehumidifier func tionwithreferencetothetarget valueset under humidity 9 ...

Page 10: ...edesired day Step 2 Select thefirst heating mode Normal withtheindex finger select thedesired lengthof time Theselected period iscolored by selecting thecolor of theoperating mode normal orange Step 3 Continuetothenext mode Turbo and proceed asdescribed above select thetimeperiod for theTurbo Mode Step 4 Continuetothenext mode Eco and proceed asdescribed above select thetimeperiod for theEco Mode ...

Page 11: ...ormationcannot be excluded Subject asa basicprincipletoerrorsand technicalchanges Date and time of installation Name of installation company Space for notes Your specialist dealer Manufacturer SORELGmbH Mikroelektronik Reme Str 12 D 58300Wetter Ruhr 49 0 233568277 0 49 0 233568277 10 info sorel de www sorel de Version 03 07 2018 11 ...

Reviews: