background image

Expert Menu

Overview > Operating Mode > Main Menu > Expert

Language Selection
The configuration of the device language.

Date & Time
The configuration of the time and date and
automatic summer/winter changeover.

Settings
Settings concerning basic functions such as
sensor calibration, location and com-
missioning.

Service values
Information about the device version and mes-
sages such as restarts.

Factory Settings
The factory settings are restored in the device.

Expert Menu Settings

Overview > Operating Mode > Main Menu > Expert > Settings

Functions
Management of local control functions -
Thermostat and dehumidifier.

Location
Set where the device is installed (selection of
the room icon).

Sensor calibration
Used to adapt the temperature and humid-
ity of the said local sensor for the selected
area.

Display
Adjustment of display brightness.

8

Summary of Contents for CALEON

Page 1: ...Installation and operating instruction CALEON Thermostat Read carefully before installation commissioning and operation ...

Page 2: ...ts 3 Description CALEON Thermostat 4 Specifications 4 Scopeof supply 4 Installation 5 CALEON Installation 5 Samplewiring 6 Setup 6 Setup procedure 6 Operation 7 Overview of temperatures humidity 7 Select Operating Mode 7 MainMenu 7 Expert Menu 8 Expert MenuSettings 8 SettingsFunctions 9 Set OperationHours 10 Set OperationHours 10 2 ...

Page 3: ...ty for damagecaused throughimproper usageor non complianceof thismanual Changes to the Unit l Changes additionstoor conversionof theunit arenot permitted without writtenpermissionfrom themanufacturer l It islikewiseforbiddentoinstalladditionalcomponentsthat havenot beentested together withtheunit l If it becomesclear that safeoperationof theunit isnolonger possible for examplebecauseof damagetothe...

Page 4: ...issible Ambient Conditions during operation 0 C 50 C nomoisturecondensationpermitted for transport storage 0 C 60 C nomoisturecondensationpermitted Measuring range Outsidethemeasuring rangestherearelarger deviations Internaltemperaturesensor 0 C 60 C Accuracy 1 C Resolution0 1 C Internalsensor for rel humidity 0 100 Accuracy 6 C Resolution0 1 1 Wiretemperaturesensors Optional without function Othe...

Page 5: ...e g radi atorsand windowsmust beavoided Strip cablesby 75mm max and strip thelast 7 10mm of thewires Unscrew thescrew removethecable cover and connect theelectricas described Only mainsvoltage no SELV Refit thebaseand fastenwithscrew Switchonmainsvoltageand place CALEON inoperation Thecommissioning canbe accessed inthe CALEON menuunder Expert at any time 5 ...

Page 6: ...nstall device Installthedeviceasdescribed see Samplewiring onpage6 Set Functions Assigna switching output totherespectivefunctionvia the Expert menuinthe Settings menuitem under Functions and parameterizeit see Set tingsFunctions onpage9 6 ...

Page 7: ...ystheselected location room Minus Plus Changethetarget temperature 0 5 C Main menu Navigatetothemainmenu Operating modes Specifieswhichoperating mode Normal Comfort Ecoand Off isselected Theselec ted modeisshownincolor By pressing the plusand minuskeysit ispossibletoadjust thesetpoint temperatureof themodes Main Menu Overview Operating Mode Main Menu Periods Adjustment of individualheating times f...

Page 8: ...rvice values Informationabout thedeviceversionand mes sagessuchasrestarts Factory Settings Thefactory settingsarerestored inthedevice Expert Menu Settings Overview Operating Mode Main Menu Expert Settings Functions Management of localcontrolfunctions Thermostat and dehumidifier Location Set wherethedeviceisinstalled selectionof theroom icon Sensor calibration Used toadapt thetemperatureand humid i...

Page 9: ...ing output of thefunction Hysteresis Heating hysteresis of thethermostat functioninrelationtothe actualset room temperature Dehumidifier Output Switching output of thefunction Humidity Setpoint of humidity Hysteresis Hysteresisof thedehumidifier func tionwithreferencetothetarget valueset under humidity 9 ...

Page 10: ...edesired day Step 2 Select thefirst heating mode Normal withtheindex finger select thedesired lengthof time Theselected period iscolored by selecting thecolor of theoperating mode normal orange Step 3 Continuetothenext mode Turbo and proceed asdescribed above select thetimeperiod for theTurbo Mode Step 4 Continuetothenext mode Eco and proceed asdescribed above select thetimeperiod for theEco Mode ...

Page 11: ...ormationcannot be excluded Subject asa basicprincipletoerrorsand technicalchanges Date and time of installation Name of installation company Space for notes Your specialist dealer Manufacturer SORELGmbH Mikroelektronik Reme Str 12 D 58300Wetter Ruhr 49 0 233568277 0 49 0 233568277 10 info sorel de www sorel de Version 03 07 2018 11 ...

Reviews: