EN 19
6
Insert cartridge
1.
Open the injection cartridge. Please note the use-by date of the injection
mortar to be processed. Combined and dried-out cartridges result in overload
and damage of the device. Cartridges with an expired use-by date should be
disposed of in accordance with the instructions on the injection cartridge.
2.
Screw open the mixing nozzle, according to the instructions on the injection
cartridge. Only use unused mixing nozzles. Already used nozzle can damage
the cordless dispenser.
3.
With the help of the retract button, the gear rod can be retracted together with
all the rods. The prepared cartridge can then be inserted into the cartridge
holder.
4.
After the cartridge has been inserted cleanly into the cartridge holder, the
injection rod can be pushed forward. The rods should be easily pushed into the
cartridge until they reach the depth stop.
Summary of Contents for 344027