XR-CA430X
15
15
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the frequency counter becomes 3,000 Hz.
Specified Value: Constant speed
Adjustment Location:
Tape Speed Adjustment
– SET UPPER VIEW –
SECTION 4
MECHANICAL ADJUSTMENTS
TAPE TENSION MEASUREMENT
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
TORQUE MEASUREMENT
Mode
Torque Meter
Meter Reading
2.95 – 6.37 mN•m
Forward
CQ-102C
(30 – 65 g•cm)
(0.42 – 0.90 oz•inch)
Forward
0.05 – 0.44 mN•m
CQ-102C
(0.5 – 4.5g•cm)
Back Tension
(0.01 – 0.06 oz•inch)
2.95 – 6.37 mN•m
Reverse
CQ-102RC
(30 – 65 g•cm)
(0.42 – 0.90 oz•inch)
Reverse
0.05 – 0.44 mN•m
CQ-102RC
(0.5 – 4.5g•cm)
Back Tension
(0.01 – 0.06 oz•inch)
5.89 – 19.61 mN•m
FF, REW
CQ-201B
(60 – 200 g•cm)
(0.83 – 2.78 oz•inch)
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 60 g
(more than 2.12 oz)
Reverse
CQ-403R
more than 60 g
(more than 2.12 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
0 dB=0.775 V
Tape Speed Adjustment
Setting:
Frequency counter
2,955 to 3,075 Hz
TAPE DECK SECTION
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
set
AUDIO OUT jack (J331)
–
+
10 k
Ω
TUNER SECTION
Tuner section adjustments are done automatically in this set.
SECTION 6
DIAGRAMS
6-1.
NOTE FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS
Note on Schematic Diagram:
• All capacitors are in
µ
F unless otherwise noted. pF:
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
•
C
: panel designation.
•
A
: B+ Line.
• Power voltage is dc 14.4V and fed with regulated dc power
supply from ACC and BATT cords.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
no mark : FM
(
) : AM
〈〈
〉〉
: TAPE PLAYBACK
∗
: Impossible to measure
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: TAPE PLAYBACK
L
: BUS AUDIO IN
Note on Printed Wiring Board:
•
X
: parts extracted from the component side.
•
Y
: parts extracted from the conductor side.
•
: Pattern from the side which enables seeing.
Caution:
Pattern face side:
Parts on the pattern face side seen from
(Conductor Side)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Component Side) the parts face are indicated.