13
XR-CA300/CA320/CA320X
SECTION 3
MECHANICAL ADJUSTMENTS
SECTION 4
ELECTRICAL ADJUSTMENTS
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 5.89 mN•m
(more than 60 g)
Reverse
CQ-403R
(more than 2.12 oz)
• Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking
compound to the parts after the azimuth adjustment.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
CQ-102C
(1.5 – 4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Reverse
0.15– 0.39 mN•m
CQ-102RC
(1.5 –
4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
(50 – 150 g•cm)
(0.69 – 2.08 oz•inch)
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Seek/Stop Level and AM Auto Seek/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
Press the
[OFF]
button, if the clock is not displayed.
2. Push the
[4]
button.
3. Push the
[5]
button.
4. Press the
[1]
button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the
[OFF]
button.