XDP-PK1000
8
1. OUTLINE
By using test mode, operation check for EQ switch, audio output
check and software version check can be performed.
Note:
Before returning the DSP unit to customer, return the EQ and IN-
PUT SELECT setting to customer’s original setting state.
EQ switch
INPUT SELECT switch
2. FUNCTION OF TEST MODE
The following operation becomes possible in test mode.
• The EQ setting is
fl
atly
fi
xed, and the setting of ALO is
fi
xed
off.
• MIN/MAX of the sound setting can con
fi
rm it by sliding the
switch.
• The software version can be con
fi
rmed.
3. ENTERING TEST MODE
Procedure:
1. Connect 14 pin of battery harness or jig-land (JL114) on DSP
board (conductor side) to GND, then press [RESET] button.
Position of 14 pin of battery harness
Position of jig-land (JL114) on DSP board (conductor side)
2. Make sure that the [SOURCE] indicator LED is lit violet color
for 3 seconds, it means that test mode turns on.
After 3 seconds
Violet
Blue
Releasing method:
Turn the power off.
SECTION 4
TEST MODE
Note:
Test mode of XDP-MU100 has been described in this sec-
tion. Test mode doesn’t exist in XA-C100IP.
4. SOUND TEST VIA SWITCH
Fader, SubVolume, Balance can be changed by EQ setting switch
in test mode (Refer to table for details).
Assigned of functions
in test mode.
Fader Select
Front
Rear
Center
Left
Right
Center
SubVolume
-7Step
(MUTE)
0Step
Initial Position
Balance Select
Sub
Volume
Balance
Fader
The other position
Switch Position
Center
0 step
0 step
Sound Settings
Fader
Sub Volume Balance
Center
Center
0 step
REAR 7
(Max)
0 step
Center
LEFT 7
(Max)
Center
0 step
Center
FRONT 7
(Max)
RIGHT 7
(Max)
-7 step
(Mute)
Center
Center
Each switch effects are mixed.