![Sony XCL-U100 Technical Manual Download Page 37](http://html.mh-extra.com/html/sony/xcl-u100/xcl-u100_technical-manual_418403037.webp)
Ca
mer
a
Cont
rol Comma
nds
Command Specification
37
Setting Value Accession Command
x
Setting Value Accession
[Command] RMEM
([Parameter 1]) <Setting value selection (None, 1 - 2)>
None: Camera setting value accession
1: Filter factor accession
2: LUT value accession
[Process] Sends the data which can be set by Serial
communication and the camera information
(version) to the camera control application.
Another command is not accepted during
transmission of data.
[Data transmission] Transmits data continuously in each
category.
The transmitting data are shown in decimal number.
The followings are transmission format and the
transmission examples.
<Transmission format>
<Category>: <Data 1>, <Data 2>, <Data 3>, ...,
<CRLF>
<Transmission example>
CA: 1.00 <CRLF>
AF: 0, 0, 1023, 1023, ..., <CRLF>
SH: 0 <CRLF>
..
.
OK <CRLF>
Setting Values
Category
name
Content
Data
number
Data
CA
Camera
information
1
<Version>
AF
AFE
2
<AFE gain>, <Pedestal>
SH
Shutter
3
<Shutter speed>, <Shutter speed adjusting value>, <Shutter speed fine-adjusting>
TR
Trigger
6
<Trigger mode>, <External trigger pulse polarity>, <Trigger overlap mode>,
<Trigger delay>, <Start time adjusting value>, <End time adjusting value>
BR
Binarization
2
<Binarization mode>, <Binarization threshold value>
DG
Digital
6
<Digital gain mode>, <Digital gain step>, <Digital pedestal mode>, <Digital
pedestal-step>, <Digital clamp mode>, <Digital clamp-step>
GM
Gamma
1/2
<Gamma mode>, When Gamma mode 4, 5: <Gamma>, <Gamma offset>
FL
Filter
1
<Filter mode>
BN
Binning
1
<Binning mode>
PT
Partial
6
<Partial scan mode>, <Partial scan read beginning position>, <Partial scan read
ending position>, <Horizontal partial scan mode>, <Horizontal partial scan
beginning column number>, <Horizontal partial scan ending column number>
IO
IN/OUT
5
<Trigger signal input selection>, <Grayscale output mode>, <Signal Output Bit
Depth>, <DC IN connector signal output setting>, <Serial communication speed
setting>