35
Sensor Readout (Sensor Output)
This signal indicates that exposure has completed and the image sensor has entered the video output sequence (enabled
only when operating the trigger mode). Output is available from the GPO2 or 3 terminals. The sensor readout signal is
asserted before optical black (OB) and the effective pixel area is output. Image might not be output properly, if trigger
signal is input while this signal is asserted.
Pulse Train Generator
Pulse waveforms can be output from the GPO connector. Available range is 0.5Hz to 100kHz.
Status LED
LED on the rear panel lights up according to the output specification set for GPO1 connector. Various settings are
possible such as assigning the trigger signal and pulse train generator. The setting is saved immediately and reflected at
the next startup.
The LED will light rapidly if the power is supplied via the single camera link cable with the Camera configuration set
to Medium, Full, or 80 bit.
Command
Parameter
PULSE-DUTY
1 to 2000000 [µs]
PULSE-CYCLE
10 to 2000000 [µs]
Command
Parameter
Setting
LED-MODE
0
Off
1
On
2
GPO1 setting
3
GPO2 setting
4
GPO3 setting
5
GPO4 setting
Trigger signal
Exposure signal
Sensor readout signal
(Sensor output)
Trigger latency