F
unc
tions
Timing Chart
28
Timing Chart
Horizontal timing
Constant regardless of the trigger mode, binning, and partial scanning. DVAL and LVAL are the same signal.
* When CAMERALINK-TAP=1. The value will be half during 2tap output.
Start time is shifted according to the OFFSETX value.
Vertical timing
E: Varies depending on the EXP, OFFSETY value or trigger latency.
sensor-tap
STROBE
A
B
XCL-S600/C
1
54 MHz
3184*
WIDTH*
2
84 MHz
2772*
WIDTH*
4
84 MHz
2772
WIDTH
XCL-S900/C
1
54 MHz
3872*
WIDTH*
2
84 MHz
3402*
WIDTH*
4
84 MHz
3402
WIDTH
sensor-tap
C
D
n
XCL-S600/C
1
24 + OFFSETX
3184 - WIDTH - C
HEIGHT
2
13 + OFFSETX
2772 - WIDTH - C
HEIGHT
4
13 + OFFSETX
2772 - WIDTH - C
HEIGHT / 2
XCL-S900/C
1
24 + OFFSETX
3872 - WIDTH - C
HEIGHT
2
13 + OFFSETX
3402 - WIDTH - C
HEIGHT
4
13 + OFFSETX
3402 - WIDTH - C
HEIGHT / 2
LVAL
DVAL
STROBE
Video output
Trigger
FVAL
LVAL
Video output