Trigger Control
19
Trigger Control
Free run/Trigger mode
Free run
The camera operates without a trigger signal and performs the video output operation continuously after the shutter
(exposure) is finished. The horizontal and vertical timing signals are generated within the camera. During the free-run
operation, image pickup timing cannot be controlled. In the free-run operation, the adjustment is made automatically to
achieve the maximum frame rate according to the shutter setting.
Trigger mode
Exposure is started by detecting the externally input trigger signal. When EXP-MODE is 0, exposure is started by
detecting the rising or falling edge of the trigger signal and the trigger edge detection (exposure is performed based on
the set shutter value) is performed. When EXP-MODE is 1, the trigger width detection (exposed for the period of the
trigger signal width) is performed.
For trigger mode (TRG-MODE=1)
Trigger edge detection
The figure shows the trigger signal negative polarity (detecting the drop edge).
Trigger width detection
The figure shows the trigger signal negative polarity (detecting Low level width).
command
param
Setting
TRG-MODE
0
Free run
1
Trigger mode
command
param
Setting
EXP-MODE
0
Trigger edge detection
1
Trigger width detection
Trigger signal
Exposure
Sensor output
Trigger signal
Exposure
Sensor output