Fu
n
c
tio
n
s
Camera mode
18
Trigger partial scan mode
In this mode the partial scan action begins through
synchronization with the external trigger input.
Set T1 in order to comply with the following formula. Refer to the partial mode regarding A and B.
T1 > 0.0315 × (A+B) [msec]
1
T1
T2
T3
A
A
1
A
* T4
2448CLK
72CLK
Vertical timing
Example of positive electrode (The horizontal timing is the same as in the normal mode.)
FVAL
LVAL
DVAL
Image output
TRG
* Only one LVAL is less than 2448CLK during T4 length in order
to adjust the timing. T4 changes by depending on T1.
Trigger mode
T1
T2
Shutter
T3 [ms]
Edge detection mode
See the formula under
this table.
More than 10 usec
OFF
66.86
1/15s
66.86
1/30s
33.52
1/100s
10.18
1/120s
8.52
1/250s
4.18
1/500s
2.18
1/1000s
1.2
1/2000s
0.7
1/5000s
0.4
1/10000s
0.3
1/7.5s
Impossible
setting
1/2s
1s
2s