16
Notes on Microphone System Operation
•
To operate with 2 or more channels, maintain a distance
of at least 30 cm (1 ft.) between each pair of transmitters.
For details of operation with 2 or more channels, refer to
the Operating Instructions for the WRR-810A UHF
Synthesized Tuner and WRR-820A/840A/850A/860A
UHF Synthesized Diversity Tuners.
•
Ensure that the tuners set to channels not being used are
either turned off or set to the minimum output level.
•
When powering the transmitter on or off, to keep the
noise to a minimum, set the audio output level from the
tuner or mixer to a minimum.
•
Powering the transmitter on without checking the channel
selection first may interfere with the operation of other
microphones/transmitters, if the current setting is already
being used.
Operation
Changing in transmit mode
You can also change the input attenuation setting during
transmission.
1
When the attenuation setting is indicated on the display,
press and hold the SET/DISPLAY button for more than
1 second.
The ATT indication flashes.
2
Press the + or – button to select the attenuation setting in
the same manner as in setting mode.
3
Press the SET/DISPLAY button.
The ATT indication stops flashing.
(Or leave the unit without pressing any button for more
than 5 seconds. The flashing automatically stops and
normal transmit mode is resumed.)
Summary of Contents for WRT-860A