3-1
WRT-807B (U/CE)
Section 3
Electrical Alignment
3-1. Equipment and Tools
Equipment Required
Name
Specifications
Model Name
DC Power Supply
Output regulated voltage : 0 to 5 Vdc, 2 A
_
DC Ammeter
Measurement range
: 300 mA
_
Spectrum Analyzer
Frequency
: 10 kHz to 4 GHz
ADVANTEST R3371B or equivalent
Modulation Analyzer RF input Frequency
: 150 kHz to 3 GHz
ANRITSU MS616A or equivalent
RF Power Meter
Range
: 3
u
W to 100 mW
HEWLETT PACKARD 435B (with Power sensor HEWLETT
with Power sensor
PACKARD 8482A) or equivalent
Audio Analyzer
Oscillator
: 20 Hz to 100 kHz
HEWLETT PACKARD 8903B (with A-weighted filter) or equivalent
Distortion meter
S/N meter
Level meter
Frequency Counter
Frequency
: 10 Hz to 1000 MHz HEWLETT PACKARD 5385A or equivalent
Effective digits
: 10 digits
Resolution
: 0.1 Hz
Oscilloscope
Frequency
: DC to 10 MHz
_
1
Digital Volt Meter
Effective digit
: 3 / digits
_
2
Tools Required
Name
Part No.
Remarks
SMA-BNC (J) connector
J-6402-490-A
For RF signal input
RF conversion connector
J-6402-400-A
For RF signal input
AF input cable
_
For AF signal input
Refer to the “How to make a AF input cable”.
Adjustor (0.4
x
1.3 mm)
7-721-052-81
LRT driver
J-6402-350-A
For Grip A removal
How to make a AF input cable
Required parts
AF input connector ;1 (Part No. J-6402-470-A)
Cable with BNC connector ; 1 (Part No.1-555-758-00)
1 pin (black)
2 pin (white)
Solder.
Shield
3 pin (orange)
Cable with BNC connector
AF input connector (female)