9
(GB)
Transport and storage conditions
Temperature –10 to +40°C
Humidity
0 to 90%
Pressure
700 to 1060 hPa
Dimensions
Approx. 217
×
217
×
352.5 mm (w/
h/d) (8
5
/
8
×
8
5
/
8
×
14 inches)
(not incl. projecting parts and
controls)
Mass
Approx. 8.5 kg (18 lb 12 oz) (not
incl. battery packs)
Accessory supplied
AC power cord (1)
Cable with an 8-pin connector (1)
Operation Manual (1)
Tally plate (1)
AC plug holders (1)
Pin Assignment
Y/C IN connector (4-pin mini DIN)
1
2
4
3
Pin No.
Signal
Description
1
Y-input
1 Vp-p, sync negative, 75 ohms
2
CHROMA
286 mVp-p (NTSC)
sub-carrier-input
300 mVp-p (PAL), burst
Delay time between Y and C:
within 0 ±100 nsec., 75 ohms
3
GND for Y-input
GND
4
GND for
GND
CHROMA-input
REMOTE connector (8-pin mini DIN)
1
2
3
6
7
8
4
5
Pin No.
Signal
1
4 : 3/16 : 9
2
H/V delay
3
GND
4
INT/EXT SYNC
5
Tally
6
Underscan/normal scan
7
A/B or SDI/LINE
8
LINE/RGB
For remote control, connect the pin of the desired
function to pin 3 (GND).
Design and specifications are subject to change
without notice.