31
SW OUT Terminal
The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
Specify the interval between each pulse signal on the
SET UP 4 display. Also, set TIMING to FIELD or
FRAME depending on the specifications of the camera
switcher.
Available settings are:
FIELD: 1, 2, 3, 4, 5, 10, 30, or 60 fields
FRAME: 1, 2, 3, 4, 5, 10, 30, or 60 frames
1
Press MENU until the SET UP 4 display appears
on the screen.
01 of FIELD is flashing.
2
Set the interval by pressing DATA
‘
/
’
and press
SHIFT
b
.
3
Set TIMING to FIELD or FRAME by pressing
DATA
‘
/
’
.
4
Set 3H (3-hour mode) to Y (yes) or N (no) by
pressing DATA
‘
/
’
.
Y (yes): a signal is output in the 3-hour mode
N (no): a signal is not output in the 3-hour mode
5
When you have completed the settings, press
PAUSE to return to the normal display.
1
Press MENU until the SET UP 3 display appears
on the screen.
2
Press SHIFT
v
to move the flashing to TAPE END
OUT and set to –3M or END by pressing DATA
‘
/
’
.
3
Press PAUSE to return to the normal display.
SW OUT terminal
COM terminal
<SET UP 3>
ALARM MODE
ALARM SPEED
ALARM DURATION
TAPE IN MODE
TAPE END MODE
TAPE END OUT
CLOG DETECT.
Y1
3H
20S
STOP
REW
-3M
Y
<SET UP 4>
∗
SW OUT
FIELD
TIMING
3H
<USED TIME>
01
FIELD
Y
<SET UP 4>
∗
SW OUT
FIELD
TIMING
3H
<USED TIME>
04
FIELD
Y
<SET UP 4>
∗
SW OUT
FRAME
TIMING
3H
<USED TIME>
04
FRAME
Y