3-5
SRX-R320
Message No.
Error message
Trouble
Remedy
FAIL_19
LENS ERROR
Focus operation is failed.
Check the lens and lens cable. Check the
SY board. Replace the SY board if it is
damaged.
FAIL_21
ADJUSTMENT ERROR
The Z-axis operation is failed.
Check the lamp house-supplied motor and
harness. Replace the motor if it is dam-
aged. Check the SY board. Replace the
SY board if it is damaged.
FAIL_24
ADJUSTMENT ERROR
Calibration is failed.
Perform recalibration, check the lamp
(luminance deterioration). Replace the
lamp bulb if it is deteriorated.
FAIL_25
DEVICE ERROR
FPGA con
fi
guration fails.
Turn off the power once, then turn on it
again.
FAIL_26
DEVICE ERROR
I
2
C communication error.
Turn off the power once, then turn on it
again.
FAIL_27
DEVICE ERROR
LVDS error
Turn off the power once, then turn on it
again.
FAIL_28
DEVICE ERROR
PLL error
Turn off the power once, then turn on it
again.
FAIL_29
DEVICE ERROR
Parity error
Turn off the power once, then turn on it
again.
FAIL_30
BALLAST ERROR
The power unit for lamp is interlocked.
Turn off the power once, then turn on it
again.
FAIL_34
ADJUSTMENT ERROR
The Z-axis is gotten out of range in the
+
direction.
Readjust the Z-axis and save it. Return
the Z-axis in the
_
direction.
(Refer to Section 2-2.)
FAIL_35
ADJUSTMENT ERROR
The Z-axis is gotten out of range in the
_
direction.
Readjust the Z-axis and save it. Return
the Z-axis in the
+
direction.
(Refer to Section 2-2.)
FAIL_36
DEVICE ERROR
Setting error of DVI.
Check the setting and set the operation
again.
Summary of Contents for SRX-R320
Page 1: ...DIGITAL CINEMA PROJECTOR SRX R320 INSTALLATION MANUAL 1st Edition ...
Page 4: ......
Page 6: ......
Page 44: ...1 38 SRX R320 1 14 Dimensions Front Left Exhaust Barycentric position Barycentric position ...
Page 46: ......
Page 125: ......
Page 126: ...Sony Corporation SRX R320 SY E 9 968 659 01 Printed in Japan 2009 10 22 2009 ...